
A high accuracy AC and DC power calibrator suitable for calibrating watt-meters, power meters, and kW-Hr meters. Supplied with its own “PC Virtual Control” software allowing the user full control via laptop or PC. Frequency can be set in 0.1Hz steps from 45 to 400Hz, and phase in 0.1degree steps. Alternatively power factor (PF) can be set in 0.01 steps. The output can be displayed as VA or Watts.
The standard maximum AC current output (22A) can be extended to 100A by using an optional 100A current transformer. This extends the maximum power to 0.1MW/MVA. A clamp meter adaptor option is also available (1 and 50 turns).
EasyCal - Manage, Automate and Optimise the Calibration Process
The 5077 can also be controlled using Time Electronics’ EasyCal software. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001,ISO 17025, and other international quality standards.
| DC Voltage |
|---|
| Range | Accuracy 1 year | Output Resistance | Max Output Current | Resolution |
|---|---|---|---|---|
| *2V | 0.01% + 500μV | < 0.5Ω | 20mA | 1μV |
| *20V | 0.01% + 500μV | < 0.5Ω | 20mA | 10μV |
| 300V | 0.02% + 30mV | < 5Ω | 20mA | 100μV |
| 1050kV | 0.05% + 50mV | < 10Ω | 10mA | 1mV |
*Accuracy is specified at minimum current output.
| DC Current |
|---|
| Range | Accuracy 1 year | Compliance Voltage | Resolution |
|---|---|---|---|
| 2A | 0.03% + 500μA | 5V | 100μA |
| 22A | 0.05% + 6mA | 4V | 1mA |
| AC Voltage (45Hz to 400Hz 0.02% accuracy) |
|---|
| Range | Accuracy 1 year | Output Resistance | Max Output Current | Resolution |
|---|---|---|---|---|
| *2V | 0.03% + 500μV | < 0.5Ω | 20mA | 100μV |
| *20V | 0.03% + 2mV | < 1Ω | 20mA | 1mV |
| **300V | 0.06% + 30mV | < 5Ω | 20mA | 10mV |
| **1050kV | 0.08% + 90mV | < 10Ω | 10mA | 100mV |
*Accuracy is specified at minimum current output.
**Accuracy is specified at 100Hz for current outputs less than 5A.
| AC Current (45Hz to 400Hz 0.02% Accuracy) |
|---|
| Range | Accuracy 1 year | Compliance Voltage | Resolution |
|---|---|---|---|
| 2A | 0.1% + 2mA | 3.5V | 100μA |
| 22A | 0.1% + 20mA | 3V | 1mA |
| Phase Angle (Applies to outputs above 22 Volts) |
|---|
| Frequency | Range | Accuracy 1 year | Resolution |
|---|---|---|---|
| 45 to 99Hz | -90.0 to +90.0 deg | 0.3 deg | 0.1 deg |
| 100Hz to 400Hz | -90.0 to +90.0 deg | 1 deg | 0.1 deg |
| Power Factor |
|---|
| Frequency | Range | Resolution |
|---|---|---|
| 45 to 400Hz | 0.00 to 1.00 | 0.01 |
The accuracy of the power is complex and is determined by using a formula, which combines the errors due to Voltage, Current, and Phase.
Power Accuracy (%) = SqrRt (Voltage accuracy2 + Current accuracy2 + Phase Correction2)
Where Phase Correction (%) = 100x(1-Cos(Phase+PhaseAcc)/Cos Phase)
| Warm up | 1 Hour to full accuracy |
| Settling Time | Less than 5 seconds |
Standard Interfaces |
GPIB (IEEE-488), RS-232, USB |
| Temp Performance | Operating: 0 to 40°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C |
| Operating Humidity | < 80% non-condensing |
| Operating Altitude | 0 to 3km. Non operating: 3km to 12km |
| Line Power | 100 - 230V AC 50/60Hz. Power Consumption 60W typical, 80W Max. |
Dimensions |
W440 x H198 x D580mm (17.6 x 7.8 x 32.8”) |
| Weight | 25kg (36lbs) |
| Country of Origin | UK |
Supplied With |
Virtual control software, user manual, RS-232 cable, and USB adaptor/cable |
| Models |
|---|
5077 |
Power Calibrator |
| Options |
|---|
9790 |
100 Amp AC Current Transformer - View data sheet |
9780 |
Clamp Meter Adaptor (1 & 50 turn coil) - View data sheet |
| 9735 | Test Lead Set |
| C160 | Factory Calibration Certificate (NPL traceable) |
| C124 | UKAS Calibration Certificate (ISO 17025) |
| Calibration Software and Accessories |
|---|
ECFLA |
EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support. |
| 9795 | Printer & Connectivity Kit (Printer, DVD-RW, 4 Port USB Hub, Numeric Key Pad & USB Memory Stick) |
| 9777 | Bar Code Reader |
| 9778 | Cal and ID Label Printer |
| 9779 | Job and Address Label Printer |
| 9597 | GPIB Cable |
| 9743 | PCI - GPIB interface card |
9794 |
GPIB - USB Adaptor |
ESP1 |
EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades. |
| ESP2 | EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades. |
| EOT1 | EasyCal Online Training Session (Via Remote Desktop) |
| PDF Downloads |
|---|
| File Name | File Size | Language |
|---|---|---|
621kB | EN | |
235kB | EN | |
284kB | EN | |
4MB (low resolution) | EN | |
8MB (Higher resolution) | EN |