The 5065 is a high performance, versatile 6½ digit bench multimeter with 19 measurement functions.
Low cost, simple operation, stability, and high accuracy make the 5065 an ideal DMM for a variety of applications. In addition high speed means both the sampling rate and the data transfer rate can achieve 2000 readings per second.
The comprehensive range of features makes the 5065 suitable for test engineers, R&D, service, and calibration technicians. The durable construction with a protective rubber guard and carry handle allows convenient bench top use, and transportability.
The front panel features a two-line, colour-coded display for easy to read measurements and functions. Control is simple, with common functions selected from a single button press.
The 5065 measures AC/DC voltage, AC/DC current, 2/4 wire resistance, frequency, period, diode, continuity, thermocouples and RTD.
In addition to standard functions many other capabilities such as Min/Max, Ratio/% and Null are included. Memory functions with up to 2000 readings can be stored and recalled. Limit testing with an external output can be configured to signal pass or fail.
The USB interface enables connectivity to a PC. A basic setup and graphing application is supplied as standard. Add-in utilities for Microsoft Excel and Word allow simple data collection directly into a spreadsheet or document.
An optional 10 channel scanner card is available which allows multiple inputs to be measured. Further options are test lead sets, GPIB and RS232 interfaces, and an RTD probe adaptor.
Calibration made easy
Connect the 5065 to a PC/Laptop installed with Time Electronics’ EasyCal software and automate the calibration process. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.
| DC Voltage |
|---|
| Range | Resolution | Input Resistance | Accuracy |
|---|---|---|---|
| 100.0000mV | 0.1μV | > 10GΩ | 0.0050 + 0.0035 |
| 1.000000V | 1.0μV | > 10GΩ | 0.0040 + 0.0007 |
| 10.00000V | 10μV | > 10GΩ | 0.0035 + 0.0005 |
| 100.0000V | 100μV | 10MΩ | 0.0045 + 0.0006 |
| 1000.000V | 1μV | 10MΩ | 0.0045 + 0.0010 |
| DC Current |
|---|
| Range | Resolution | Shunt Resistance | Accuracy |
|---|---|---|---|
| 10.000000mA | 10nA | 5.1Ω | 0.05 + 0.02 |
| 100.00000mA | 100nA | 5.1Ω | 0.05 + 0.005 |
| 1.000000A | 1μA | 0.1Ω | 0.1 + 0.01 |
| 3.00000A | 10μA | 0.1Ω | 0.12 + 0.02 |
| AC Voltage |
|---|
| Range | Resolution | Frequency (Hz) | Accuracy |
|---|---|---|---|
100.0000mV | 0.1μV | 3 to 5 | 1.00 + 0.04 |
1.000000V | 1.0μV to 1mV | 3 to 5 | 1.00 + 0.03 |
| AC Current |
|---|
| Range | Resolution | Frequency (Hz) | Accuracy |
|---|---|---|---|
1.000000A | 1μA | 3 to 5 | 1.00 + 0.04 |
3.000000 | 10μA | 3 to 5 | 1.10 + 0.06 |
| Resistance |
|---|
| Range | Resolution | Test Current | Accuracy |
|---|---|---|---|
| 100.0000Ω | 100μΩ | 1mA | 0.01 + 0.004 |
| 1.000000kΩ | 1mΩ | 1mA | 0.01 + 0.001 |
| 10.00000kΩ | 10mΩ | 100μA | 0.01 + 0.001 |
| 100.0000kΩ | 100mΩ | 10μA | 0.01 + 0.001 |
| 1.000000MΩ | 1Ω | 5μA | 0.01 + 0.001 |
| 10.00000MΩ | 10Ω | 500nA | 0.04 + 0.001 |
| 100.0000MΩ | 100Ω | 500nA | 0.8 + 0.01 |
Diode Test |
|
|
|
Continuity |
|
|
|
| Frequency and Period |
|---|
| Range | Frequency (Hz) | Accuracy (% of reading) |
|---|---|---|
100mV to 750V | 3 to 5 | 0.1 |
| Temperature |
|---|
| RTD Types | PT100, D100, F100, PT385 or PT3916. (Best Accuracy ±0.08°C ) |
| Thermocouple Types | J, K & T (Accuracy ±0.5°C ). E (Accuracy ±0.6°C ). R, S & B (Accuracy ±5°C ) |
| Standard Interfaces | RS-232 and USB (GPIB optional) |
| Line Power | 100 - 230V AC 50/60Hz |
| Dimensions | W210 x H85 x D350mm |
| Weight | 4.4kg |
For a full list of options please see the Models/Options tab.
| Models |
|---|
5065 |
Bench Digital Multimeter |
| Options |
|---|
| 9714 | 10 Channel Scanner card |
| 9715 | GPIB Interface (replaces standard fitted RS232 interface) |
| 9717 | RTD Probe Adaptor |
| 9713 | Carry Case with test lead compartment |
9541 |
Basic Test Lead Set - View data sheet |
9796 |
Premium Test Lead Set - View data sheet |
| C173 | Factory Calibration Certificate (NPL traceable) |
| C117 | UKAS Calibration Certificate (ISO 17025) |
| Calibration Software and Accessories |
|---|
ECFLA |
EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support. |
| 9795 | Printer & Connectivity Kit (Printer, DVD-RW, 4 Port USB Hub, Numeric Key Pad & USB Memory Stick) |
| 9777 | Bar Code Reader |
| 9778 | Cal and ID Label Printer |
9779 |
Job and Address Label Printer |
| ESP1 | EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades. |
| ESP2 | EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades. |
| EOT1 | EasyCal Online Training Session (Via Remote Desktop) |
| PDF Downloads |
|---|
| File Name | File Size | Language |
|---|---|---|
370kB | EN | |
3MB (Low resolution) | EN | |
7MB (Higher resolution) | EN | |
172kB | EN |