5051Plus Multifunction Calibration System

5051Plus Multifunction Calibration System

Features

  • Combined calibrator/DMM/PC
  • 0 - 1050V & 0 - 22A (AC/DC)
  • Source up to 1GΩ resistance
  • Thermocouple simulate/measure
  • PT100, C & L, scope calibration
  • Clamp meter calibration
  • EasyCal Software included
 

Calibrator / DMM / Touch Screen PC 
The 5051Plus combines a precision multifunction calibrator, 6½ digit multimeter, and industrial touch screen PC. Offering high performance calibration and maximum functionality, it provides the foundation for an efficient calibration program. By integrating the calibrator, DMM and PC in one unit minimal bench space is used in the laboratory. This is also beneficial for field calibration work as the 5051Plus replaces the need for transporting several instruments.

Calibrator
The standard unit is fitted with AC/DC voltage to 1050V, AC/DC current to 22A, variable resistance to 120MΩ (with 1GΩ fixed value), capacitance and inductance, conductance, thermocouple simulation and oscilloscope calibration. Also supplied is a clamp meter adaptor for clamp calibration up to 1100A, and test lead set to provide the neccessary connections for nearly all applications. Further enhancements can be made by optional adaptors and accompanying benchtop instruments. Both manual control and EasyCal software control is available.  

Digital Multimeter
The internal 6½ digit multimeter measures DC voltages to 1000V, AC voltages to 750V, resistance to 100MΩ, and frequency to 300kHz.
Operation can be performed using the manual control program or EasyCal software. 

Touch Screen PC
The operating system is Windows XP embedded, running on a 2GHz PC which allows standard peripherals to be connected. The calibrator and DMM control programs allows the wide range of functions to be easily selected using mouse, keyboard, or touch screen. As a complete workstation the 5051Plus is supplied with printer and connectivity kit for producing certificates, reports, and labels. 

Multi Instrument Calibration
The 5051Plus can calibrate digital and analogue multimeters, frequency meters, ohm meters, AC/DC millivoltmeters, decade boxes, thermocouple indicators and sensors, clamp meters, oscilloscopes, timer counters, RTDs and much more. Accompanying instruments and adaptors can be added for power supplies, pressure devices, and more.

EasyCal Software - Manage, Automate and Optimise the Calibration Process
The 5051Plus comes pre-loaded with Time Electronics’ EasyCal software. Automate the calibration process and increase speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards. Data can be transferred to desktop PCs/servers using USB memory or connected to a LAN via the ethernet connection located on the rear of the unit.

Technical Specifications

Standard Features - Calibrator
Function Range Best 1 year Specification
Voltage DC 0 to ± 1050V ± 15ppm of setting
Current DC 0 to ± 22A ± 80ppm of setting
Voltage AC 1mV to 1050V (10Hz to 20kHz, sine-wave) ± 300ppm of setting
Wideband AC Voltage 20 to 200mV/300kHz. 0.2 to 2V/1MHz. 2 to 20V/100kHz ± 0.05% of setting
Current AC 10μA to 22A (20Hz to 1kHz, sine-wave) ± 0.05% of setting
Clamp Meter Adaptor x50 turn AC/DC Current up to 1100A (DC, 45 to 90Hz) ± 0.5%
Capacitance 1nF, 10nF, 100nF, 1μF, 10μF, 100μF (100V max) ± 0.25% of setting
Inductance 1mH, 1.9mH, 5mH, 10mH, 19mH, 50mH, 100mH, 190mH, 500mH, 1H, 10H ± 0.1% of setting

Resistance

1Ω to 120MΩ variable (plus 1GΩ fixed value)

± 100ppm of setting

Conductance 1s to 1ns (Fixed values, decade steps) ± 20ppm of setting
Thermocouple Simulation -270 to 1800°C (Type J, K, R, T, S, B, E, N) ± 0.15°C

PT100 Simulation

-180 to 850°C

± 0.2°C

Oscilloscope Calibration
- Amplitude
- Frequency/Period
- Duty Cycle
- Fast-Rise
- 2.2GHz Sweep (opt 9769)


0mV to 200V and 0mV to 2V 50Ω (square-wave or DC)
0.1Hz to 100MHz / 100ns to 10s
3 frequencies: 100Hz, 1kHz, 10kHz, settable from 0 to 100%
<850ps. Bandwidth checking up to 400MHz
100MHz to 2.2GHz levelled sine-wave (0.5, 1, 1.5V pk-pk)


± 0.05%
± 20ppm (± 0.1ppm - opt 9783) 

 
 
Amplitude ± 1%, Freq ± 20ppm

Standard Features - Internal DMM 6.5 Digit
Function Range Best 1 year Specification
Voltage DC 0 to 1000V 35ppm of rdg + 6ppm of rng
Current DC 0 to 3A 500ppm of rdg + 50ppm of rng
Voltage AC 0 to 750V 0.06% of rdg + 0.04% of rng
Current AC 0 to 3A 0.1% of rdg + 0.04% of rng
Resistance 0 to 100MΩ 100ppm of rdg + 50ppm of rng
Frequency 3Hz to 300kHz 0.01% of rdg
Thermocouple -270 to 1800°C (Type J, K, R, T, S, B, E, N) ± 0.5°C
PT100 -180 to 850°C ± 0.08°C
Standard Features - Internal PC Specifications / Details
Processor 2GHz
RAM 512MB
Hard Drive 60GB Solid State
Ports 4 x USB, 1 x Fast Ethernet
Display 10.5in LCD (Touch Screen)
Operating System Windows XP Embedded

Pre-loaded Software

Calibrator and DMM control programs, EasyCal calibration software suite

Supplied With

USB keyboard, Inkjet Printer, Cal and ID Label Printer, DVD-RW, 4 port USB hub, Numeric key pad, USB memory stick 


Options

Oscilloscope Calibration Options

9769: Internal Scope 2.2GHz Levelled Sine Generator

9783: Internal Oven-Controlled High Stability Frequency Reference

9762: External Rubidium High Stability Frequency Reference

9764: External Current Probe Calibration Adaptor 

External Adaptors

& Instruments 

9773: Optical Tacho Adaptor

9764: Current Probe Calibration Adaptor

9790: 100 Amp AC Current Transformer

9760: Power Amplifier (60V AC, 90V DC - 100mA)

7042: Remote Pressure Module (Vac to 20 bar versions)

5077: Power Calibrator

7070/7071/7072: Dry Block Calibrators 

EasyCal Accessories

& Calibration Certificates 

9777: Bar Code Reader

9779: Job and Address Label Printer

EC2FL/EC2CL/EC2WL: Additional User Licenses for separate PCs

EAD: EasyAdmin Add-On

EWC: WebCerts Add-On

CREP: Crystal Reports Software

C134: UKAS Calibration Certificate 


General Specifications

Warm up 30 minutes to full accuracy
Settling Time Less than 5 seconds
Temp Performance Operating: 5 to 40°C, Full Spec: 22°C +/- 3°C, Storage: -10°C to 50°C
Operating Humidity <80% non condensing
Operating Altitude 0 to 3km. Non operating: 3km to 12km
Line Power 100 to 230V AC 50/60 Hz. 200W maximum
Dimensions W430 x H202 x D538mm
Weight 23kg

Supplied Items

5051PLUS Calibration System

Clamp Meter Adaptor

Premium Test lead Set

Soft Carry Case

USB keyboard, Inkjet Printer, DVD-RW, 4 port USB hub, Numeric key pad, USB memory stick 

Cal and ID Label Printer

5051 Manual Control Software (Calibrator and DMM)

EasyCal Calibration Software

Factory Calibration Certificate (NPL traceable) 

Country of Origin UK
Models

5051+

Multifunction Calibration System Package

Precision Calibrator/DMM/PC with Clamp Meter Adaptor, Premium Test lead Set, Carry Case, Printer & Connectivity Kit, Label Printer, Manual Control Software, EasyCal Software, & Factory Calibration Certificate.

Options

9769

Internal Scope 2.2GHz Levelled Sine Generator (see specifications tab for details)

9783

Internal Oven-Controlled High Stability Frequency Reference (increases frequency accuracy from 20ppm to 0.1ppm)

9762

External Rubidium Frequency Reference - View data sheet

9764

Current Probe Calibration Adaptor - View data sheet

9773

Optical Tacho Adaptor - View data sheet

9759 Torque Wrench Calibration Adaptor

9790

100 Amp AC Current Transformer - View data sheet

9760

Power Amplifier (60V AC, 90V DC - 100mA) - View data sheet

5077

Power Calibrator - View data sheet

9766

External Low Noise Attenuator 1000:1 - View data sheet

9767

External Low Noise Attenuator 100:1 - View data sheet

7042

Remote Pressure Module (Vacuum, 0.2, 2, 5, 10, or 20bar)  -  View data sheet

9758

DC Electronic Load (80A, 80V, 300W) for power supply calibration - View data sheet

7070 Dry Block Calibrator (-17 to 140°C)
7071 Dry Block Calibrator (33 to 320°C)

7072

Dry Block Calibrator (33 to 650°C)

C134 UKAS Calibration Certificate (ISO 17025)
Calibration Software Accessories and Support Packages
9777 Bar Code Reader

9779

Job and Address Label Printer

9794 USB - GPIB Adaptor

9765

USB - RS232 Adaptor

ESP1 EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades.
ESP2 EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades.
EOT1 EasyCal Online Training Session (Via Remote Desktop)
PDF Downloads
File Name File Size Language

5051Plus Data Sheet

400kB

EN

5051Plus Extended Specifications

155kB

EN

5051Plus Brochure

1.64MB (Low resolution)

EN

5051Plus Brochure

6.4MB (Higher resolution)

EN

EasyCal Brochure

3MB (Low resolution)

EN

EasyCal Brochure

7MB (Higher resolution)

EN

9780 Clamp Meter Adaptor Data Sheet

165kB

EN

Test Lead Sets Data Sheet

172kB

EN

Data sheets for various options shown in Models/Options tab