5045 Oscilloscope Calibrator

5045 Oscilloscope Calibrator

Features

  • 1mV to 220V square wave/DC
  • Frequency 0.1 to 100MHz
  • Time markers 10s to 10ns
  • Fast rise <300ps
  • Front panel or PC control
  • 2GHz sweep & rubidium options
  • EasyCal software compatible
 

Quick and Easy Oscilloscope Calibration to 600MHz
The 5045 is a versatile, high accuracy calibrator capable of calibrating digital and analogue oscilloscopes, timer/counters, and frequency meters.
It provides a wide range of outputs for amplitude, frequency, period and bandwidth. Amplitude calibration is achieved by a DC signal or 1kHz square-wave, ranging from 1mV to 220V (2V max for 50 ohm loads). Deviation up to ±9.99% allows fine adjustment of amplitude and direct readout of error. 

Accurate frequencies are generated from a temperature controlled quartz crystal oscillator. Alternatively a 10MHz reference input in can be used. Timing accuracy of 0.1ppm is suitable for most oscilloscopes and timer counters. A precise square-wave output provides a fast rise time of less than 300ps, which allows bandwidth testing up to 600MHz.

Simple Operation
Functions and ranges are easily accessed from the front panel. Increase and decrease keys per digit, are used to quickly set the output value. Deviation control then enables the user to finely adjust the output value as a percentage (+/-9.99%). All this information is shown on an easy to read LED display.

Virtual Front Panel Software
The 5045 is supplied as standard with Time Electronics’ windows based ‘Virtual Front Panel’ interface. This enables the user to control the instrument via a laptop or PC. 

2GHz Levelled Sine-Wave Option
For precise bandwidth determination and frequency response analysis the 2GHz option is available. The ability to sweep the frequency output from 10MHz to 2GHz and adjust the amplitude from 0.5V to 1.5V pk-pk ensures accurate analysis of oscilloscope input amplifiers.

Current Probe Calibration
For calibration of oscilloscope current probes an external adaptor is available. This converts the 5045’s amplitude output to current and covers the range 0.1mA to 100mA pk-pk, 0.2% accuracy, DC or 1kHz.

Rubidium frequency reference
Enhanced timing performance is available by specifying the rubidium high stability frequency reference option (9762). This option achieves timing accuracies required to calibrate high performance timer/counters to 1 part in 10^10.

EasyCal Software - Manage, Automate and Optimise the Calibration Process
To automate the oscilloscope calibration process the 5045 can be controlled using Time Electronics’ EasyCal calibration software. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.

Technical Specifications

Standard Features
Function Range Specification (± output + floor) Resolution

Frequency*

0.1Hz to 10MHz
20MHz to 100MHz

± 0.1ppm
± 20ppm

Fixed Outputs in 1,2,5,10 Sequenced Steps

Period*

10s to 100ns
50ns to 10ns

± 0.1ppm + 30ps
± 20ppm + 50ps

Fixed Outputs in 1,2,5,10 Sequenced Steps

Duty Cycle

100Hz, 1kHz, 10kHz

Settable from 0 to 100%

-

Amplitude DC or 1kHz Square wave

2mV to 200mV
200mV to 20V
20V to 220V
1mV to 200mV (50Ω)
200mV to 2V (50Ω)

± 0.2% + 10μV
± 0.05% + 10μV
± 0.05% + 10μV
± 0.25% + 15μV
± 0.25% + 15μV

10μV
1mV
10mV
100μV
1mV

Fast Rise

10MHz (200mV pk/pk)

Rise Time less than 300ps

-

*Frequency amplitude: 1.5V pk-pk 0.1Hz to 100kHz. 1V pk-pk 200kHz to 100MHz.


Options (order code in brackets)

2GHz Sweep (9769)

- Levelled Sine-Wave
- Settable Amplitudes


100MHz to 200MHz, 1%, 200MHz to 500MHz, 4% , 500MHz to 1GHz, 10% , 1GHz to 2GHz, 20%
0.5V, 1V, 1.5V pk-pk

Rubidium Reference (9762)

Rubidium atomic clock 10MHz frequency reference.
Increases accuracy to 1 part in 10*10 (Applies to 10MHz Max output on 5045).

Current Probe Adaptor (9764)

Battery powered external adaptor for checking current probes.

0.1 to 100mA, 0.2% accuracy.

Full details on the available external options are shown in the Models / Options tab.


General Specifications

Warm up 30 minutes to full accuracy
Settling Time Less than 5 seconds
Standard Interfaces GPIB (IEEE-488), RS-232, USB
Temp Performance Operating: 10 to 40°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C
Operating Humidity < 80% non-condensing
Operating Altitude 0 to 3km. Non operating: 3km to 12km
Line Power 100 - 230V AC 50/60Hz. Power Consumption 60W typical, 80W Max.
Dimensions W450 x D272 x H152mm (18 x 11 x 7”)
Weight 8.2kg (18lbs)
Country of Origin UK

Supplied With

Virtual control software, user manual, RS-232 cable, and USB adaptor/cable

Models

5045

Oscilloscope Calibrator

Options

9769

Internal Scope 2GHz Levelled Sine Generator

9762

Rubidium High Stability Frequency Reference  -  View data sheet

9764

Current Probe Calibration Adaptor  -  View data sheet

9519 9 Piece Adaptors and Test Lead Set
9728 19” Universal Rack Mount Kit
C147 Factory Calibration Certificate (NPL traceable)
C128 UKAS Calibration Certificate (ISO 17025)
Calibration Software and Accessories

ECFLA

EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support. 
For further licenses and EasyCal add-ons see the Easycal web page or PDF brochure

9795

Printer & Connectivity Kit (Printer, DVD-RW, 4 Port USB Hub, Numeric Key Pad & USB Memory Stick)

9777 Bar Code Reader
9778 Cal and ID Label Printer

9779

Job and Address Label Printer

ESP1 EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades.
ESP2 EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades.
EOT1 EasyCal Online Training Session (Via Remote Desktop)
PDF Downloads
File Name File Size Language

5045 Data Sheet

557kB

EN

EasyCal Brochure

4MB (Low resolution)

EN

EasyCal Brochure

8MB (Higher resolution)

EN

9762 Rubidium Frequency Standard Data Sheet

173kB

EN

9764 Current Probe Adaptor Data Sheet

295kB

EN