A precision instrument designed to calibrate RCD, loop, insulation, earth testers and multifunction installation testers. The 5030 accurately simulates RCD trip times and measures currents produced by RCD testers. It replicates loop impedance and auto adjusts for local line impedance. It also provides insulation resistances and measures test voltages and currents.
Simple Operation and Automated Calibration
User control is via the central navigation keypad. Scrolling though menus and settings is intuitive and easy, with measurements and settings shown on the large clear LCD display. Alternatively connect the 5030 to a PC/laptop (via RS232 or USB) installed with Time Electronics’ EasyCal software and automate the calibration process. Increase speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.
Regional Test Sockets and Fault Detection
For loop and RCD tests the electrical tester (device under test) connects directly to the dedicated front panel mains socket. The 5030 can be fitted with a number of regional type sockets (specified on order). In these test conditions, if the device under test is faulty, the 5030 auto detects the fault, disconnects the output and warns the user. The 5030 is designed not to trip any RCDs on the local supply.
Loop Impedance with Auto Local Loop Compensation
With 10 measurement points the 5030 covers a wide range of loop testers. The precision resistors that make up the loop calibration function are high power and capable of withstanding up to 40A. An accurate automatic measurement of the local loop is made by the 5030 and added to the resistor value to give the loop impedance value, allowing for precise loop impedance calibration.
Precise RCD Trip Times
Set between 10 and 2000ms, with an accuracy of 0.1ms. Predefined values are available for quick selection via the front panel. Alternatively any value, with 1ms resolution, can be set via EasyCal calibration software. To avoid false trip times the 5030 incorporates a 'pre-test trigger delay' setting. This feature is for use with RCD testers that produce a pre-test signal. A test current threshold setting (0 to 100% of nominal current) is also user selectable.
RCD Current Measurements
RCD current measurements are true RMS for AC, half wave rectified and DC. The ranges covered are from 6mA to 1000mA, with multipliers of x0.5, x1, x2, and x5 up to a maximum of 2500mA.
Insulation Resistance and Test Voltage Measurement
The 5030 tests the functions of megohm meters using precision high value resistors up to 2GΩ, accurately measuring test voltages up to 1kV under 0.5mA or 1mA test conditions. Short circuit current measurement is also available up to 3mA.
Continuity and Earth Resistance
The 5030 precision low ohm resistors allow calibration of continuity functions found on most multifunction testers and insulation testers. Test voltages and currents are also measured.
Mains Voltage and Frequency
The local mains supply voltage and frequency is precisely measured by the 5030. This is used to cross reference the voltage reading on the unit under test and confirm the instruments accuracy.
| Loop |
|---|
| Function | Range / Values | Resolution | Accuracy |
|---|---|---|---|
Loop Impedance | 1800, 330.0, 180.0, 33.00, 18.00, 3.300, | 4 digit | ±0.5% of displayed value ± 10mΩ |
| Local Loop Compensation | 0 to 9.999Ω | 0.001Ω | ±0.5% of value ± 10mΩ |
| Test Current | 40A max (200ms) / 50W max | – | – |
| RCD |
|---|
| Function | Range / Values | Resolution | Accuracy |
|---|---|---|---|
Trip Time | 10, 20, 30, 40, 50, 60, 80, 100, 300, 500, 1000, 1500, 2000ms | 1ms | ±0.1ms |
Current | 6.000, 10.00, 30.00, 100.0, 300.0, 500.0, 1000mA | 4 digit | ±0.5% of reading. ±1% with x5 multiplier |
| Current Multipliers | x0.5, x1, x2, x5 | – | – |
| Maximum Current | 2500mA | – | – |
| Waveforms | AC, DC, half wave rectified | – | – |
| Phase Detection | 0° or 180° | – | – |
| Pre Trigger Delay | 0 to 2000ms | – | – |
| Pre Trigger Threshold | 0 to 100% of nominal current | – | – |
| Insulation (Option ICO1) |
|---|
| Function | Range / Values | Resolution | Accuracy |
|---|---|---|---|
Resistance | 1MΩ to 2000MΩ | 1MΩ | 1% of value |
Test Voltage Measurement | 50.0 to 99.9V DC | 0.1V | 1% of reading |
Short Circuit Current | 0.00 to 300.00mA DC | 0.01mA | 1% of range |
| Continuity (option ICO1) |
|---|
| Function | Range / Values | Resolution | Accuracy |
|---|---|---|---|
Resistance | 0.1Ω to 100.0Ω | 0.1Ω | 1% of value |
Test Voltage Measurement | 0.0 to 50.0V DC | 0.1V | 0.5% of range |
Test Current Measurement | 0 to 400mA DC | 1mA | 0.5% of range |
| Power Dissipation | 1 watt maximum | – | – |
| Voltage |
|---|
| Function | Range | Resolution | Accuracy |
|---|---|---|---|
| Line Voltage Measurement | 200.0 to 260.0V RMS | 0.1V | 0.5% of reading |
| Line Frequency Measurement | 45.00 to 65.00Hz | 0.01Hz | 0.1% of reading |
| Warm up | 30 minutes to full accuracy |
| Settling Time | Less than 5 seconds |
| Standard Interfaces | RS-232 and USB |
Temp Performance |
Operating: 10 to 35°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C |
| Operating Humidity | < 80% non condensing |
| Operating Altitude | 0 to 3km. Non operating: 3km to 12km |
| Line Power | 220 - 240V AC 50Hz. Power Consumption 200W max |
| Dimensions | W430mm x H155mm x D255mm |
| Weight | 8kg |
| Country of Origin | UK |
| Supplied With | User manual, RS-232 cable, USB adaptor/cable |
| Models |
|---|
| 5030 | Electrical Tester Calibrator |
| Options |
|---|
| ICO1 | Insulation and Continuity |
| C201 | Factory Calibration Certificate (NPL traceable) |
| C137 | UKAS Calibration Certificate (ISO 17025) |
| Calibration Software and Accessories |
|---|
ECFLA |
EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support. |
| 9795 | Printer & Connectivity Kit (Printer, DVD-RW, 4 Port USB Hub, Numeric Key Pad & USB Memory Stick) |
| 9777 | Bar Code Reader |
| 9778 | Cal and ID Label Printer |
| 9779 | Job and Address Label Printer |
| ESP1 | EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades. |
| ESP2 | EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades. |
| EOT1 | EasyCal Online Training Session (Via Remote Desktop) |
| PDF Downloads |
|---|
| File Name | File Size | Language |
|---|---|---|
300kB | EN | |
3MB (Low resolution version) | EN | |