
A high performance multi-product calibrator that provides the foundation for fast and cost-effective calibration. Designed for a wide workload the 5025 can be used to accurately test and verify both traditional and new test equipment.
The standard unit is fitted with AC/DC voltage to 1050V, AC/DC current to 22A, digital frequency to 10MHz, decade resistance to 1GΩ, conductance and thermocouple simulation. Further options enhance calibration capabilities and can be added as per customer requirement.
Multi Instrument Calibration
The 5025 can calibrate various instruments and devices; digital and analogue multimeters, frequency meters, ohm meters, AC/DC millivoltmeters, thermocouple indicators, clamp meters, temperature indicators, timer counters, oscilloscopes, and much more.
Simple Operation
Functions and ranges are easily accessed from the front panel. Increase and decrease keys per digit, are used to quickly set the output value. Deviation control then enables the user to finely adjust the output value as a percentage (+/- 9.999%). All this information is shown on an easy to read LED display.
Flexible Options
A range of options provide added functionality and features. Internal additions include capacitance and inductance, wideband AC voltage, full range resistance (incorporating PT100 simulation), power calibration, and oscilloscope calibration. External adaptors are available for clamp meter calibration (up to 1100A), optical tachometer calibration, and torque wrench calibration. Also available are accompanying instruments that can be used with the 5025 for specific applications. These include low noise attenuators, a 100A current transformer, and a power amplifier for demanding analogue instruments.
EasyCal Software - Manage, Automate and Optimise the Calibration Process
Connect the 5025 to a PC/Laptop (via RS233, GPIB or USB) installed with Time Electronics’ EasyCal software and automate the calibration process. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.
| Function | Range | Best 1 year Specification |
|---|---|---|
| Voltage DC | 0 to ± 1050V | ± 15ppm of setting |
| Current DC | 0 to ± 22A | ± 80ppm of setting |
| Voltage AC | 1mV to 1050V (10Hz to 20kHz, sine-wave) | ± 300ppm of setting |
| Current AC | 10μA to 22A (20Hz to 1kHz, sine-wave) | ± 0.05% of setting |
| Resistance | 1Ω to 1GΩ (Fixed values, decade steps) | ± 20ppm of setting |
| Conductance | 1S to 1nS (Fixed values, decade steps) | ± 20ppm of setting |
| Thermocouple Simulation | -270 to 1800°C (Type J, K, R, T, S, B, E, N) | ± 0.15°C |
10MHz Digital Frequency/Period | 0.1Hz to 10MHz / 100ns to 10s | ± 20ppm of setting |
| Option (code in brackets) | Range / Values | Best 1 year Specification |
|---|---|---|
| Wideband AC Voltage (9771) | 20 to 200mV/300kHz. 0.2 to 2V/1MHz. 2 to 20V/100kHz | ± 0.05% of setting |
| Capacitance (9798) | 1nF, 10nF, 100nF, 1μF, 10μF, 100μF | ± 0.25% of setting |
Inductance (9798) | 1, 1.9, 5, 10, 19, 50, 100, 190, & 500mH, 1H, 10H | ± 0.1% of setting |
Full Range Resistance (9787) | 1Ω to 120MΩ (Variable) | ± 100ppm of setting |
Oscilloscope Calibration (9770) |
|
|
Power Calibration (9797) | 22A, 1050V, 23kW, 45 to 400Hz | ACV: 0.03%, DCV: 0.01% |
| Warm up | 30 minutes to full accuracy |
| Settling Time | Less than 5 seconds |
| Standard Interfaces | GPIB (IEEE-488), RS-232, USB |
Temp Performance |
Operating: 5 to 40°C, Full Spec: 22°C +/- 3°C, Storage: -10°C to 50°C |
Operating Humidity |
< 80% non condensing |
| Operating Altitude | 0 to 3km. Non operating: 3km to 12km |
| Line Power | 100 to 230V AC 50/60 Hz. 200W maximum |
| Dimensions | W455 x H155 x D480mm |
| Weight | 16.5kg |
| Country of Origin | UK |
| Supplied With | User manual, RS-232 cable, and USB adaptor/cable |
For a full list of options please see the Models/Options tab.
For full specifications and further details please see the PDF Data Sheets in the Download tab.
| Models |
|---|
5025 |
Multifunction Calibrator |
| Internal Options |
|---|
| 9798 | Capacitance (1000pF - 100μF) / Inductance (1mH - 10H) |
| 9774 | Simulated Resistance (10Ω - 40MΩ) |
| 9787 | Full Range Resistance (1Ω - 120MΩ) - incorporating PT100 Simulation |
| 9771 | Wideband AC Voltage (1MHz Max. 20mV - 20V) |
| 9797 | Power Calibration (0 - 20KW AC and DC) |
| 9770 | Oscilloscope Calibration (1mV - 200V, 0.1Hz - 100MHz) |
| 9769 | Scope 2.2GHz Levelled Sine Generator |
| 9783 | Oven-Controlled Frequency Reference (9770 scope option must be fitted) |
| External Options and Calibration Certificates |
|---|
9762 |
Rubidium Frequency Reference (9770 Scope option must be fitted) - View data sheet |
9764 |
Current Probe Calibration Adaptor (9770 Scope option must be fitted) - View data sheet |
5065 |
6.5 Digit Bench Multimeter - View data sheet / View web page |
9780 |
Clamp Meter Adaptor (1 & 50 turn coil) - View data sheet |
9773 |
Optical Tacho Adaptor - View data sheet |
9790 |
100 Amp AC Current Transformer - View data sheet |
9760 |
Power Amplifier (60V AC, 90V DC - 100mA) - View data sheet |
9766 |
External Low Noise Attenuator 1000:1 - View data sheet |
9767 |
External Low Noise Attenuator 100:1 - View data sheet |
9759 |
Torque Wrench Calibration Adaptor |
| 9085 | Soft Carry Case for 5025 |
| 9728 | 19” Universal Rack Mount Kit |
9541 |
Basic Test Lead Set - View data sheet |
9796 |
Premium Test Lead Set - View data sheet |
C159 |
Factory Calibration Certificate (NPL traceable) |
| C103 | UKAS Calibration Certificate (ISO 17025) |
| C113 | Extended UKAS Calibration Certificate (ISO 17025) |
| Calibration Software and Accessories |
|---|
ECFLA |
EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support. |
9795 |
Printer & Connectivity Kit (Printer, DVD-RW, 4 Port USB Hub, Numeric Key Pad & USB Memory Stick) |
| 9777 | Bar Code Reader |
| 9778 | Cal and ID Label Printer |
9779 |
Job and Address Label Printer |
| 9743 | PCI - GPIB interface card |
| 9794 | USB - GPIB Adaptor |
| 9597 | GPIB Cable |
9588 |
RS-232 Cable |
| ESP1 | EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades. |
| ESP2 | EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades. |
| EOT1 | EasyCal Online Training Session (Via Remote Desktop) |
| PDF Downloads |
|---|
| File Name | File Size | Language |
|---|---|---|
365kB | EN | |
190kB | EN | |
3MB (Low resolution) | EN | |
7MB (Higher resolution) | EN |
Data sheets for various external options shown in Models/Options tab