High Accuracy Programmable DC/AC Source
The 5018 is a versatile instrument that covers a wide range of applications. It can be configured as a simple benchtop DC voltage source or advanced AC/DC voltage and current calibrator controlled via PC or laptop, performing any number of tasks as part of a complex ATE test rig.
Ramping Feature
The 5018 includes an internal ramping feature. A ramp rate per range for each function can be set via a PC. The option to ramp the output can be turned on or off via the front panel. This is particularly useful in aviation and automotive industries for testing analogue gauges.
Simple Operation and Clear Visual Display
Simple front panel operation allows the user to quickly set the function and output required. Using the jog / shuttle dial deviation the user can finely adjust the output value as a percentage (+/- 99.99%). All this information is shown on a clear, easy to read LED display.
GPIB, RS-232, and USB Interfaces
These interfaces allow the 5018 to be connected to a PC and controlled by an external program such as Time Electronics’ EasyCal calibration software. The 5018 uses a SCPI command structure for programming. This makes writing control programs in Visual Basic, C and Labview a simple task.
EasyCal Software - Manage, Automate and Optimise the Calibration Process
Connect the 5018 to a PC or laptop (via RS-232, GPIB or USB) installed with Time Electronics EasyCal software and automate the calibration process. Increase speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.
EasyCal has the ability to control a wide range of programmable instruments and comprehensive ATE systems can be configured to control a variety of applications. It has full read back capability and therefore can perform closed loop testing. Conditional tests can be configured to allow decision making to further enhance the usefulness.
| DC Voltage (30V option 9724 shown in brackets) |
|---|
| Range | Accuracy 1 year | Output Resistance | Max Output Current | Resolution |
|---|---|---|---|---|
| 22mV (33mV) | 30ppm + 4μV | 10Ω (50Ω) | - | 100nV |
| 220mV (330mV) | 15ppm (30ppm) + 6μV | 10Ω (50Ω) | - | 1μV |
| 2.2V (3.3V) | 15ppm (20ppm)+ 20μV | < 0.15Ω | 20mA | 1μV |
| 22V (30V) | 15ppm (20ppm) + 150μV | < 0.15Ω | 20mA | 10μV |
| DC HIGH VOLTAGE OPTIONS 9720 / 9721 (9721 includes 9720 range) |
|---|
| Range | Accuracy 1 year | Output Resistance | Max Output Current | Resolution |
|---|---|---|---|---|
| 220V* | 15ppm + 1mV | <0.25Ω | 10mA | 100μV |
| 1kV* | 25ppm + 3mV | <1Ω | 1mA | 1mV |
*Minimum Load 20kΩ
| DC CURRENT OPTION 9718 |
|---|
| Range | Accuracy 1 year | Compliance Voltage | Resolution |
|---|---|---|---|
| 220μA | 150ppm + 15nA | 11V | 1nA |
| 2.2mA | 100ppm + 40nA | 11V | 10nA |
| 22mA | 80ppm + 200nA | 11V | 10nA |
| 220mA | 80ppm + 3μA | 11V | 100nA |
| AC V OPTION 9719 10Hz to 20kHz (Sine 0.01% crystal controlled) |
|---|
| Range RMS | Acc % 1yr 10Hz - 1kHz | Acc % 1 yr 1kHz - 10kHz | Acc % 1yr 10kHz - 20kHz | Output Resistance | Max Output Current |
|---|---|---|---|---|---|
| 22mV | 0.05% + 100μV | 0.05% + 150μV | 0.05% + 250μV | 10Ω | - |
| 220mV | 0.04% + 100μV | 0.04% + 150μV | 0.04% + 250μV | 10Ω | - |
| 2.2V | 0.03% + 170μV | 0.03% + 250μV | 0.03% + 300μV | <0.15Ω | 20mA |
| 22V | 0.03% + 2.0mV | 0.03% + 3.0mV | 0.03% + 4.0mV | <0.15Ω | 20mA |
| AC CURRENT OPTION 20Hz to 1kHz (Sine) - available if current and AC options are fitted |
|---|
| Range RMS | Accuracy 1 year | Compliance Voltage RMS | Resolution |
|---|---|---|---|
| 220μA | 0.07% + 300nA | 5V | 10nA |
| 2.2mA | 0.05% + 300nA | 5V | 10nA |
| 22mA | 0.05% + 3μA | 5V | 100nA |
| 220mA | 0.05% + 30μA | 5V | 1μA |
| Warm up | 1 hour to full accuracy |
| Settling Time | Less than 5 seconds |
| Standard Interfaces | GPIB (IEEE-488), RS-232, USB |
| Temp Performance | Operating: 10 to 40°C, Full Spec: 23°C +/- 5°C, Storage: -10°C to 50°C |
| Operating Humidity | < 80% non condensing |
| Operating Altitude | 0 to 3km. Non operating 3 to 12km |
| Line Power | 100 - 230V AC 50/60 Hz. Power Consumption 60W typical, 80W Max. |
| Dimensions | W450 x D272 x H152mm (18 x 11 x 7”) |
| Weight | 8.2Kg (18lbs) |
| Country of Origin | UK |
Supplied With |
User manual, RS-232 cable, and USB adaptor/cable |
| Models |
|---|
5018 |
Programmable DC/AC V/I Calibrator |
| Internal Options |
|---|
| 9718 | Current Option (220mA max) |
| 9719 | AC Option (22V max) |
| 9721 | 200V DC Option |
| 9733 | Rear panel terminals |
9720 |
1KV DC Option (includes 200V DC option 9721) |
| 9724 | 30V option |
| External Options and calibration certificates |
|---|
| 9728 | 19” Universal Rack Mount Kit |
9541 |
Basic Test Lead Set - View data sheet |
9796 |
Premium Test Lead Set - View data sheet |
9766 |
Low Noise Attenuator 1000:1 - View data sheet |
9767 |
Low Noise Attenuator 100:1 - View data sheet |
| C142 | Factory Calibration Certificate (NPL traceable) |
| C104 | UKAS Calibration Certificate (ISO 17025) |
| Calibration Software and Accessories |
|---|
ECFLA |
EasyCal Full License - when purchased with multifunction calibrator/DMM: Discounted full license with 1 year support. |
9795 |
Printer & Connectivity Kit (Printer, DVD-RW, 4 Port USB Hub, Numeric Key Pad & USB Memory Stick) |
| 9777 | Bar Code Reader |
| 9778 | Cal and ID Label Printer |
9779 |
Job and Address Label Printer |
9597 |
GPIB Cable |
| 9743 | PCI - GPIB interface card |
9794 |
GPIB - USB Adaptor |
| ESP1 | EasyCal Support Package 1: 1 year email and telephone support. Minor upgrades. |
| ESP2 | EasyCal Support Package 2: 2 year email and telephone support. Minor upgrades. |
| EOT1 | EasyCal Online Training Session (Via Remote Desktop) |
| PDF Downloads |
|---|
| File Name | File Size | Language |
|---|---|---|
380kB | EN | |
3MB (Low resolution) | EN | |
7MB (Higher resolution) | EN | |
172kB | EN | |
137kB | EN |