        <item>
            <title>RTD Temperature Calibrator</title>
            <description>It is a Hand Held instrument that combines a precision Digital Thermometer (using RTD probes), with an RTD / Ohms Calibrator.</description>
            <link>http://www.timeelectronics.co.uk/7000-rtd-temperature-calibrator.html</link>
            <guid isPermaLink="false">61811E0F-5985-4812-9C19-645E15ED6978</guid>
            <pubDate>Thu, 26 Jul 2007 18:00:50 +0530</pubDate>
        </item>
        <item>
            <title>Process Control Loop Calibrator (MET VA)</title>
            <description>It is a micro-processor based handheld process control instrument for voltage and current loop calibration and simulation.</description>
            <link>http://www.timeelectronics.co.uk/7005-loop-calibrator.html</link>
            <guid isPermaLink="false">7FA5F5FC-9124-4C37-B3E4-266A77A77A0E</guid>
            <pubDate>Thu, 26 Jul 2007 18:00:51 +0530</pubDate>
        </item>
        <item>
            <title>Loop Mate 1 – Process Control Loop Simulator</title>
            <description>Loop-Mates are single function low-cost pocket sized units, designed for process loop calibration and testing. </description>
            <link>http://www.timeelectronics.co.uk/70067007-loop-calibration-instruments.html</link>
            <guid isPermaLink="false">C63D2BB2-AE56-4C46-9CDC-B37D52038AB4</guid>
            <pubDate>Thu, 26 Jul 2007 18:00:52 +0530</pubDate>
        </item>
        <item>
            <title>Loop Mate 2 – Process Control Loop Signal Indicator</title>
            <description>Loop-Mates are single function low-cost pocket sized units, designed for process loop calibration and testing. These portable process loop instruments are part of Time Electronics&apos; comprehensive process control equipment line.</description>
            <link>http://www.timeelectronics.co.uk/70067007-loop-calibration-instruments.html</link>
            <guid isPermaLink="false">B4B374FD-1181-4067-A9CE-A235757B952E</guid>
            <pubDate>Thu, 26 Jul 2007 18:00:53 +0530</pubDate>
        </item>
        <item>
            <title>Pressure Gauge Calibrator</title>
            <description>Rugged portable pressure calibrators designed for applications from 0.2 bar up to 600 bar in eleven ranges. This single channel version allows switch selection of five pressure units. These should be specified on ordering from the following:- bar, PSI, kPa, MPa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm.</description>
            <link>http://www.timeelectronics.co.uk/7010-pressure-calibrator.html</link>
            <guid isPermaLink="false">210CD35A-E5BA-4381-8371-65BECC15C308</guid>
            <pubDate>Thu, 26 Jul 2007 18:00:54 +0530</pubDate>
        </item>
        <item>
            <title>Dual Pressure Calibrator</title>
            <description>This portable pressure calibrators designed for applications from 0.2 bar up to 600 bar in eleven ranges. For process signal calibration the loop signal is displayed on the LCD display to 0.05% accuracy. Loop drive supply (24V or 36V) is also provided.</description>
            <link>http://www.timeelectronics.co.uk/7015-dual-pressure-calibrator.html</link>
            <guid isPermaLink="false">F0FE35D3-95C6-4CAF-A9CD-A625AD99E5D0</guid>
            <pubDate>Thu, 26 Jul 2007 18:00:55 +0530</pubDate>
        </item>
        <item>
            <title>LPR Pressure Calibrator</title>
            <description>This portable pressure calibrators designed for applications from 0.2 bar up to 20 bar in nine ranges. It allows switch selection of five pressure units. These should be specified on ordering from the following:- bar, PSI, kPa, MPa, inWg, cmWg, inHg, mmHg, Kg/cm2, atm.</description>
            <link>http://www.timeelectronics.co.uk/7016-low-pressure-calibrator.html</link>
            <guid isPermaLink="false">C5ACB376-2821-4BE9-BDC4-04EAAA2C739F</guid>
            <pubDate>Thu, 26 Jul 2007 18:00:56 +0530</pubDate>
        </item>
        <item>
            <title>Digital Pressure and Current Calibrator</title>
            <description>A versatile calibrator that combines a digital pressure gauge and current indicator in one hand held instrument.</description>
            <link>http://www.timeelectronics.co.uk/7040-digital-pressure-and-current-calibrator.html</link>
            <guid isPermaLink="false">A44D68B9-A6EA-4F6A-9791-B5CFA357361D</guid>
            <pubDate>Thu, 26 Jul 2007 18:00:57 +0530</pubDate>
        </item>
        <item>
            <title>Pressure and Thermocouple Calibrator</title>
            <description>The PIC 500 Process Calibrator combines the essential functions of measurement and simulation of volts, millivolts, milliamps and ohms with the calibration of thermocouples and RTD’s. It is Time Electronics&apos; comprehensive process control equipment line.</description>
            <link>http://www.timeelectronics.co.uk/7050-process-thermocouple-calibrator.html</link>
            <guid isPermaLink="false">8A8589EC-8D73-41E4-BCB5-EDBD33E05E4F</guid>
            <pubDate>Thu, 26 Jul 2007 18:00:58 +0530</pubDate>
        </item>
        <item>
            <title>Vacuum and Pressure Calibrator Pump</title>
            <description>Vacuum and pressure calibration pump,which combines high performance with a rugged design suitable for work in all conditions. This portable pump is one of Time Electronics&apos; comprehensive process control equipment line.</description>
            <link>http://www.timeelectronics.co.uk/7090-pneumatic-calibration-pump.html</link>
            <guid isPermaLink="false">85EE26EA-86DA-4577-BFD8-DBFB6D17D87F</guid>
            <pubDate>Thu, 26 Jul 2007 18:00:59 +0530</pubDate>
        </item>
        <item>
            <title>Hydraulic Pressure Calibration Pump</title>
            <description>This Pump pump is a complete rugged solution for high pressure calibration tasks. It is supplied in a robust padded carry case complete with optional digital pressure gauge, hoses and pressure fitting accessories.</description>
            <link>http://www.timeelectronics.co.uk/7095-hydraulic-calibration-pump.html</link>
            <guid isPermaLink="false">01FBA834-9BDA-427B-9B0C-C3BD58F4B943</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:00 +0530</pubDate>
        </item>
        <item>
            <title>Modular Calibration Station</title>
            <description>This Modular Calibration Station is a uniquely flexible system offering all the benefits of made to measure design without the high cost. Designed around a 19” x 4U case and utilising a wide range of standard modules, it gives a highly flexible system that is both functional and compact.</description>
            <link>http://www.timeelectronics.co.uk/7060-modular-calibration-system.html</link>
            <guid isPermaLink="false">D3459062-F625-400B-B78B-589D887D92C9</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:01 +0530</pubDate>
        </item>
        <item>
            <title>Process and Thermocouple Calibrator</title>
            <description>It Offers Calibration facilities for both Input and Output signals. A RM5 module includes V, mA, Ohms and temperature for both thermocouples and RTD’s.</description>
            <link>http://www.timeelectronics.co.uk/7061.html</link>
            <guid isPermaLink="false">7B65856F-99BB-4DC3-8D5A-0D8B66B9A9A6</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:02 +0530</pubDate>
        </item>
        <item>
            <title>Single Pressure Modular Calibration System</title>
            <description>SINGLE PRESSURE - RM2 - A pneumatic switch and pressure regulator provide control of Input and Output of pneumatic signals.</description>
            <link>http://www.timeelectronics.co.uk/7062.html</link>
            <guid isPermaLink="false">5DF54703-3CA2-4BF5-944B-45CFE727B0E9</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:03 +0530</pubDate>
        </item>
        <item>
            <title>Dual Pressure Modular Calibration System</title>
            <description>Time Electronics Offers a Dual Pressure Modular Calibrator which is one of Time Electronics&apos; comprehensive process control equipment line.</description>
            <link>http://www.timeelectronics.co.uk/7063.html</link>
            <guid isPermaLink="false">A216BBEE-5184-49D0-A123-E4EA40442F2D</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:04 +0530</pubDate>
        </item>
        <item>
            <title>High Pressure Modular Calibrator with Regulators</title>
            <description>HIGH PRESSURE - RM3 - For High pressure calibration of both Input and Output signals the RM3 module provides safe and simple setup.</description>
            <link>http://www.timeelectronics.co.uk/7064.html</link>
            <guid isPermaLink="false">958BFEF9-3692-437F-9F1C-857B276096A8</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:05 +0530</pubDate>
        </item>
        <item>
            <title>Pressure Indicator – Modular Calibration System</title>
            <description>PRESSURE INDICATOR - RM7- A Pressure Indicator providing direct indication of applied pressure.</description>
            <link>http://www.timeelectronics.co.uk/7065.html</link>
            <guid isPermaLink="false">DF1BF857-7836-4076-86D2-A260F370DE8E</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:06 +0530</pubDate>
        </item>
        <item>
            <title>High Pressure Indicator – Modular Calibration System</title>
            <description>HIGH PRESSURE INDICATOR - RM7 - Pressure Indicator providing direct indication of applied pressure.</description>
            <link>http://www.timeelectronics.co.uk/7066.html</link>
            <guid isPermaLink="false">BF161E40-9D79-49B8-9574-0B91810C96EA</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:07 +0530</pubDate>
        </item>
        <item>
            <title>Loop Calibrator Module</title>
            <description>LOOP CALIBRATOR - RM8 - A Loop Calibrator which measures milli-Amps and Volts and supplies milli-Amps to a high accuracy.</description>
            <link>http://www.timeelectronics.co.uk/7067.html</link>
            <guid isPermaLink="false">84319BA3-9514-46A7-9F23-60A21CC82282</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:08 +0530</pubDate>
        </item>
        <item>
            <title>RTD/Ohms Calibrator</title>
            <description>RTD TEMPERATURE CALIBRATOR - RM9 - A Resistance and RTD calibrator programmable for a variety of RTD types with resistance range to 2000 ohms.</description>
            <link>http://www.timeelectronics.co.uk/7068.html</link>
            <guid isPermaLink="false">46B0F2F9-56DD-45E6-A6E0-69F35B4D4F78</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:09 +0530</pubDate>
        </item>
        <item>
            <title>Voltage and Current – V &amp; I Calibrator</title>
            <description>LOOP CALIBRATOR - RM6 - A high accuracy Loop Calibrator module. Source and measure current and volts.</description>
            <link>http://www.timeelectronics.co.uk/7069.html</link>
            <guid isPermaLink="false">3250E25E-24CD-4BB4-9813-1A7BAE2527F4</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:10 +0530</pubDate>
        </item>
        <item>
            <title>Dry Block Temperature Calibrator</title>
            <description>It is a multiple temperature probe calibrators, designed to speed up routine calibration of thermocouple and RTD probes with 2 temperature ranges available, -25 to +140 or +50 to +700°C.</description>
            <link>http://www.timeelectronics.co.uk/7070-72-dry-block-calibrators.html</link>
            <guid isPermaLink="false">B838E8C6-4F45-4374-A4D6-5D71C9A1F4F8</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:11 +0530</pubDate>
        </item>
        <item>
            <title>Installation Tester Calibrator</title>
            <description>Get This Calibrator For fast accurate calibration of electrical installation testers (UK 16th Edition). It is versatile, compact and portable calibrator designed to help electricians ensure the performance of their electrical installation test equipment is operating within specification.</description>
            <link>http://www.timeelectronics.co.uk/7671-installation-tester-calibrator.html</link>
            <guid isPermaLink="false">139B6758-5D0F-4513-98D4-13E83EE3DCE3</guid>
            <pubDate>Thu, 26 Jul 2007 18:01:12 +0530</pubDate>
        </item>
    </channel>