7005 Process Loop Calibrator

7005 Process Loop Calibrator
  • 7005 Voltage current loop calibrator

Features

  • Loop source/measure - V or I
  • Measure 0 - 25V or 0 - 125mA
  • Source 0 - 21V or 0 - 50mA
  • Accuracy 0.01%
  • Resolution 1μA or 1mV
  • Programmable ranges
  • Manual step, auto-step & ramp

7005 Images

  • A precision handheld instrument primarily used for the calibration and simulation of voltage and current loops.
    The 7005 is a high accuracy loop calibrator incorporating source and measure capabilities. The compact and lightweight design make it easily portable and ideal for plant operations and field use. Combined with user friendly controls and simple operation make this loop calibrator an excellent model for both process engineers and calibration technicians.

    The three operating modes provide a fast and easy solution to process applications; Loop current/voltage source for simulating a transmitter and the loop supply, sink of loop current for simulating a transmitter, and measurement of loop current/voltage for simulating a loop indicator.

    Manual step of the output is possible at five calibration points; 0%, 25%, 50%, 75% and 100% of span. Automatic stepping of the output is also available, both up and down with programmable dwell times.

    Continuous up/down ramping can also be performed, with user programmable ramp rates and dwell time (top and bottom).

    In source mode the range can be user programmed to any value between 0mA and 50mA, or 0V and 21V. For example a low point of 10mA and a high point of 50mA could be set giving a span of 40mA.

    Measure mode provides both voltage and current measuring capability with 5 digit resolution. Ranges are 0 to ±5V and ±5 to ±25V, 0 to ±25mA and ±25 to ±125mA. Alternatively the signal can be measured as a % of span for the following ranges; 4 to 20mA, 0 to 20mA, square root 4 to 20mA, or square root 0 to 20mA. For all measurements a Min/Max recording function is available on demand.

    An internal NiMH battery powers the unit for typically 9 hours continuous use and an external mains charger is supplied as standard. An automatic power-down feature is incorporated to conserve battery life, which can easily be disabled if not required. The unit is constructed in an impact resistant ABS case and connections are made via 4 off 4mm binding terminal posts.

  • Technical Specifications

    Voltage Source
    Range Resolution Accuracy Output Current Output Resistance
    0 to 21V 1mV ±0.01% of setting ±4mV 50mA < 1Ω
    Voltage Measure (0 to ±25V, Auto-ranging)
    Range Resolution Accuracy Measure Load
    0 to 5V 0.1mV ±0.01% of reading ±0.4mV 10MΩ
    5 to 25V 1mV ±0.01% of reading ±2mV 10MΩ
    Current Source
    Range Resolution Accuracy Output Voltage Loop Resistance
    0 to 50mA 1μA ±0.01% of setting ±2μA 22V max 1100Ω @ 20mA max
    Current Measure (0 to ±125mA, Auto-ranging)
    Range Resolution Accuracy Measure Load
    0 to 25mA 1μA ±0.01% of reading ±2μA 24.5Ω
    25 to 125mA 10μA ±0.01% of reading ±20μA 24.5Ω
    Current Sink
    Range Resolution Accuracy Min external drive Max external drive
    0 to 50mA 1μA ±0.01% of setting ±2μA 4V 40V


    Summary of Functions

    Source Mode

    • User programmable ranges - any values between 0 and 50mA or 0 and 21V.

    • Fixed ranges are available: 4 to 20mA, 0 to 20mA, sqrt 4 to 20mA, sqrt 0 to 20mA.

    • Fine adjustment (inching) is available for precise deviation from the calibration point.

    • Manual step output - five calibration points 0%, 25%, 50%, 75%, and 100%

    • Automatic step output (up/down) - five cal points with programmable dwell period.

    • Ramp output - programmable ramp rate (0 to 20mA/sec or 0 to 20V/sec) programmable dwell period (0 to 1000 seconds)

    Measure Mode

    • Voltage and current measuring capability with 5 digit resolution.

    • Ranges: 0 to ±5V and ±5 to ±25V, 0 to ±25mA and ±25 to ±125mA.

    • Signal can also be measured as a % of span on ranges: 4 to 20mA, 0 to 20mA, square root 4 to 20mA, square root 0 to 20mA.

    • For all measurements a Min/Max recording function is available on demand. 


    General Specifications

    Dimensions

    H165 x W90 x D45mm

    Weight

    0.42kg

    Operating Temperature

    -10 to 50°C

    Storage Temperature -30 to 70°C
    Operating Humidity 0 to 90% non-condensing at 25°C

    Power

    Internal rechargeable NiMH battery pack. Battery life typically 9 hours. Auto power-down feature can be enabled.
    Full recharge from being exhausted will take approximately 16 hours with the unit switched off. 

    Supplied With Battery charger, carry case, and user manual

    Optional Extras

    Calibration certificates traceable to NPL and UKAS

    Country of Origin UK
  • Models

    7005

    Voltage/Current/Loop Calibrator

    Options
    C184 Factory Calibration Certificate (NPL traceable)
    C195 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    7005 Data Sheet

    642kB

    EN

  • Request for Quotation

    7005 Process Loop Calibrator

    Product Options
    1.20

Related Products

  • 1030 Voltage and Current Source

    • 10mV, 100mV, 1V ranges
    • 10mA, 100mA ranges
    • 0.1% accuracy
    • 0 to 8V available
    • Precision 10-turn dial
    • Battery level indicator
    • Battery powered 9V PP3
    View 1030
  • 1044 Voltage and Current Calibrator

    • Measure voltage and current
    • Source voltage and current
    • 0.05% accuracy
    • 0 to 20V in 3 ranges
    • 0 to 20mA in 3 ranges
    • Battery power 9V PP3
    • Portable with carry case
    View 1044
  • 1048 Voltage/Current/Loop Calibrator

    • Source/measure current & voltage
    • 3 Source ranges to 22mA or 22V
    • 3 Measure ranges to 70mA or 50V
    • Transmitter simulator/sink
    • Output steps and ramps
    • Fine adjustment (inching)
    • Accuracy 0.02% of span
    View 1048
  • 7006 Loop Simulator & Source

    • 4 - 20mA or 0 - 10V loops
    • 7 calibration set-points
    • Accuracy 0.1%
    • TxSim and RxTest modes
    • Autostep output - adjustable rate
    • Battery powered PP3
    • Internal loop drive supply
    View 7006