Features

  • 0.95bar vacuum to 140bar (2000psi)
  • Double output manifold
  • High pressure resolution
  • High pressure stability
  • Easy to use pressure lever/handle
  • Free from humidity and dirt
  • For reference calibration with gauge

7194 Images

  • A benchtop pneumatic pressure pump that is a dual pressure source with the ability to achieve high pressures with minimal effort. It provides both 95% vacuum and pressure to 140bar (2000psi). The long pump lever with ergonomic grip enables smooth generation to high output pressures and a high-quality screw press is incorporated to allow fine adjustment settings within 0.1mbar (10Pa). The 7194 can also be used to generate low pressures (600mbar) without pumping.

    An isolation valve shuts-off the pump from the system under pressure to keep the output stable under calibration. A built-in gas-liquid trap protects the pump from moisture and dirt. Any residual liquid in the pump is vented out via the vent port which incorporates a hose connection to allow collection of liquids. For calibration applications the double output manifold provides finger-tight connections for a reference gauge and device under test.

    The 7194 is comfortable and simple operation, with features that make it ideal for calibrating pressure transducers, precision pressure gauges, and other pressure instruments. It is particularly suitable for applications where high pressure is required without the use of hydraulic pumps or nitrogen cylinders. It is also ideal for use as a benchtop gauge comparator.

    To accompany the pump Time Electronics offer a range of digital pressure gauges, including the TEG-G140b model that covers the range of the pump with 0.2/0.1/0.05/0.025% FS accuracies available. Also available is the 7078 auto-ranging digital pressure gauge with vacuum to 200bar range and 0.1% accuracy of setting.

  • Technical Specifications

    Media Air

    Generated Pressure

    0.95bar vacuum to 140bar pressure (14psi vacuum to 2000psi pressure)

    Over Pressure Range To 160bar (2320psi)
    Pressure Resolution 0.1 mbar / 10Pa

    Test Gauge Connection

    ¼” BSP

    Reference Gauge Connection

    ¼” BSP


    General Specifications

    Material Ram/adapters: 316 SS; Body: Steel/aluminum; Seals: Buna-N

    Dimensions

    Height: 178 mm (506mm with handle raised). Base: W270mm x D450mm (540mm including handle)

    Weight 7.5 kg (3.31lbs)
    Optional Extras Digital pressure gauges (ranges available upon request)
  • Models

    7194

    Benchtop Pneumatic Pressure Calibration Pump (0.95bar vac to 140bar)

    Options
    7094 Digital Pressure gauge (0 to 100bar, 0.2% FS accuracy)
    TEG-G140b Digital pressure gauge (0 to 140bar, specify accuracy - 0.2, 0.1, 0.05, 0.025% FS)
    7078 Auto-Ranging Digital Pressure Gauge (Vacuum to 200bar)
  • PDF Downloads
    File Name File Size Language

    7194 Data Sheet

    340kB

    EN

    7094 Digital Gauge Data Sheet

    216kB

    EN

    7078 Digital Gauge Data Sheet

    189kB

    EN

  • Request for Quotation

    7194 Benchtop Pneumatic Pressure Calibration Pump

    Product Options
    1.20

Related Products

  • 7078 Auto-Ranging Digital Pressure Gauge

    • Vacuum to 200bar (3000psi)
    • Accuracy 0.1% of reading
    • 9 engineering units
    • Silicone piezo resistive sensors
    • Reads gauge & absolute pressure
    • Easy to read backlit display
    • Robust with protective rubber boot
    View 7078
  • 7090 Handheld Pneumatic Pressure Calibration Pump

    • Pressure to 40bar (600psi)
    • Vacuum to -950mbar
    • Oversized check valve
    • Contoured cushioned handles
    • Protective caging for vent valve
    • Hose, fittings, & carry case supplied
    • Optional digital gauges
    View 7090
  • 7094 Digital Pressure Gauge

    • 0 to 100bar (1500psi) pressure
    • Accuracy 0.2% of full scale
    • Easy-to-read display
    • 5 digit resolution
    • 3 times per second measure speed
    • Analogue dial indicates % pressure
    • Ideal for use with the 7194 pump
    View 7094
  • 7195 Benchtop Hydraulic Pressure Calibration Pump

    • Vacuum to 700bar (10,000psi)
    • Double output manifold
    • High pressure resolution
    • High pressure stability
    • Smooth pressure generation
    • Oil or deionized water
    • For reference calibration with gauge
    View 7195
  • 7198 Pressure Calibration Accessories Kit

    • Adaptors/fittings/connectors/hoses
    • Metric/BSP/parallel/NPT adaptors
    • Coupling connectors
    • Quick release & minimess hoses
    • 10" adjustable spanner included 
    • Suitable for use with pumps
    • Compact kit for labs & on-site work
    View 7198
  • TEG Digital Pressure Gauges

    • Ranges to 2500bar (37500psi)
    • 0.02, 0.05, 0.1, 0.2% FS accuracies
    • Gauge/Absolute/Compound/Differential
    • Unique self-protection capability
    • 5 digit resolution
    • Long working period & battery life
    • 3 times per second measure speed