7191 Benchtop Low Pressure Calibration Pump

7191 Low Pressure Calibration Pump
  • 7191 Low Pressure Calibration Pump
  • 7191 with TE digital pressure gauge

Features

  • -0.95bar vacuum to 4bar (60psi)
  • Double output manifold
  • Resolution: 0.0001mbar (0.01Pa)
  • Screw press for fine adjustment
  • Bellows minimise leakage
  • Isothermal chamber for stability 
  • Compact, lightweight design

7191 Images

  • The 7191 is a hand operated pressure pump designed to generate either vacuum to -0.95 bar (-14psi) or pressures to 4bar (60psi). A high-quality screw press is designed for fine pressure adjustment, with adjusting resolution up to 0.0001mbar (0.01Pa). To reach the pressure stability as high as possible during the pressure calibration, an isothermal bellows chamber is designed for reducing the possible heat effects such as environmental temperature change. The 7191 is designed without a non-returning valve meaning minimal maintenance is required. Two finger-tight connectors installed on the pump allow the user using fingers to connect and disconnect the reference gauge and devices under test quickly and easily without the need for PTFE tape or wrenches.

    The 7191 is ideal for applications requiring accurate low pressure testing and calibration. It can be used in calibrating low pressure gauges, transmitters, or other pressure measuring instruments. Also available is the 7190 micro pressure calibration pump that provides an excellent solution to precision pressure generation between -400mbar to 400mbar.

    To accompany the pump a wide range of digital pressure gauges are available. The TEG-CV4b covers the full range of the pump (-1 to 4bar) with accuracies of either 0.2%, 0.1%, 0.05%, or 0.025% of full scale.

  • Technical Specifications

    Media Air
    Generated Pressure 0.95bar vacuum to 4bar pressure (14psi vacuum to 60psi pressure)
    Pressure Resolution 0.0001mbar / 0.01Pa 
    Material Ram/adapters: SST; Body: SST/aluminum; Seals: Buna-N (nitrile)
    Connection Finger-tight connectors for both test gauge and reference gauge
    Test Gauge Connection 1/4” BSP
    Reference Gauge Connection 1/4” BSP


    General Specifications

    Height 145 mm (5.7’’)
    Base 275 mm (10.8’’) x 260 mm (10.2’’)
    Weight 2.8 kg (6.2 lbs)
    Optional Extras TEG-CV4b: Digital Pressure Gauge (Vacuum to 4bar, 0.2/0.1/0.05/0.025% accuracies available)
    7198 Pressure accessory kit
  • Models

    7191

    Benchtop Low Pressure Calibration Pump (vacuum to 4bar)‚Äč

    Options
    TEG-CV4b Digital Pressure Gauge (Vacuum to 4bar, 0.2/0.1/0.05/0.025% accuracies available)
  • PDF Downloads
    File Name File Size Language

    7191 Data Sheet

    205kB

    EN

    TEG Digital Gauges Data Sheet

    230kB

    EN

  • Request for Quotation

    7191 Benchtop Low Pressure Calibration Pump

    Product Options
    1.20

Related Products

  • 7190 Benchtop Micro-Pressure Calibration Pump

    • -0.4bar vacuum to 0.4bar (6psi)
    • Double output manifold
    • Resolution: 0.0001mbar (0.01Pa)
    • Screw press for fine adjustment
    • Bellows minimise leakage
    • Isothermal chamber for stability 
    • Compact, lightweight design
    View 7190
  • 7193 Benchtop Pneumatic Pressure Calibration Pump

    • 0.95bar vacuum to 40bar (600psi)
    • Pneumatic
    • Double output manifold
    • Ideal for use as gauge comparator
    • High pressure resolution (0.1mbar)
    • Screw press for fine adjustment
    • Compact design ideal for field or lab
    View 7193
  • 7198 Pressure Calibration Accessories Kit

    • Adaptors/fittings/connectors/hoses
    • Metric/BSP/parallel/NPT adaptors
    • Coupling connectors
    • Quick release & minimess hoses
    • 10" adjustable spanner included 
    • Suitable for use with pumps
    • Compact kit for labs & on-site work
    View 7198
  • TEG Digital Pressure Gauges

    • Ranges to 2500bar (37500psi)
    • 0.02, 0.05, 0.1, 0.2% FS accuracies
    • Gauge/Absolute/Compound/Differential
    • Unique self-protection capability
    • 5 digit resolution
    • Long working period & battery life
    • 3 times per second measure speed
    View TEG Gauges