MENU
UK
  • EN
  • FR
  • ES
Search
Tel: +441732355993

7018 Differential Pressure Calibrator

7018 Differential Pressure Calibrator
  • 7018 Differential pressure calibrator

Features

  • 0.2, 2, 5 & 10bar versions
  • Accuracy 0.04% of full scale
  • Pneumatic
  • Over-pressure alarm
  • Isolated 24/36V loop supply
  • Loop current measure
  • Mains or battery powered

7018 Images

  • The 7018 is a differential pressure calibration system suitable for field and laboratory calibration work of both diffential pressure and electrical process loop signals. The instrument is designed for very stable measurement of differential pressures between its two output ports, enabling the calibration of differential pressure gauges, transducers, and transmitters. There are five available versions, according to the required range, either 0.2, 2, 5, or 10bar.

    Features include a 4.5 digit LCD display with 4 selectable pressure units plus mA, zeroing switch, and two quick release connector ports (Hi and Lo for differential pressure input) that are situated on the front panel of the unit. Best accuracy is 0.04% of full scale.

    For process signal calibration the loop signal is displayed on the LCD display to 0.05% accuracy. Loop drive supply (24V or 36V) is also provided. Both pressure and loop signal can be displayed at the same time to speed up the calibration of pressure transmitters. Additionally a continuity function is available for testing for open circuit loops.

    Power is via internal rechargeable cells (24 hours typical use) with a built-in mains charger. The unit can be powered directly from the mains if required. The 7018 is housed in an impact resistant safety case that provides protection and increased durability. Pressure connections are on the front panel and the instrument is supplied with a pressure hose, electrical test lead, 2 electrical probes and 2 crocodile clips.

    Options
    For the 7018, input pressure can be generated by the 7090 pneumatic hand pump (-950mbar to 40bar). Additional pumps and accompanying gauges are also available.

    For process control signal simulation Time Electronics’ handheld 7006 Loop-Mate is available as an option. It provides 4 - 20mA and 0 - 10V signals at levels of 0%, 10%, 25%, 50%, 75%, 90%, 100%. It can also step through these set points automatically to allow hands free calibration. It is battery powered and can be stored in the 7018’s supplied carry pouch.

    The 7018 is fitted with RS-232 connection as standard. Display readback can be performed using EasyCal calibration software. With comprehensive features EasyCal can simplify and speed up calibration procedures. Easily produce calibration certificates and reports to international quality standards.

  • Technical Specifications

    Specifications are for 1 year at 23ºC ±5ºC. Accuracy includes linearity and long term effects.
    All accuracies are ±1 digit. For operation outside specified temperature range, apply 70ppm per °C
    Pressure
    Range (bar) 0 to ±0.2 0 to ±2 0 to ±5 0 to ±10

    Accuracy (% of fs)

    0.1

    0.04

    0.04

    0.04

    Resolution (bar)

    0.01mb

    .0001

    .001

    .001

    Units

    0.2bar version: mbar, PSI, kg/cm2, cmWg and mA.
    2, 5, and 10bar versions: bar, PSI, kg/cm2, cmWg and mA.

    Maximum Static Pressure 10bar
    Sensor Piezo-resistive - stainless steel diaphragm
    Over pressure warning 1.2 x range full scale - audio and visual (on LCD) warning

    Fittings

    Quick Release

    Electrical
    Range Loop current measurement 0 to 200mA
    Resolution 10μA
    Resistance Loop load 5Ω
    Accuracy 0.05% of reading ±1 digit
    Loop Drive 24V or 36V switch selectable, 50mA max - isolated and with short circuit protection
    Continuity Threshold: 100Ω with audio and visual warning
    Terminals 4mm industry standard terminal posts


    General Specifications

    Power Source Internal rechargeable NiMH batteries, or mains supply (230V or 110V 50/60Hz)
    Battery Life 24 hrs of typical usage between charges
    Display 7 segment LCD with ‘Low Battery’ warning indicator
    Interfaces RS-232 for readback and re-calibration (software not supplied)
    Case Structural resin which is weather-proof to IP66 standard
    Dimensions W270 x H175 x D250mm
    Weight 3kg

    Supplied with

    1 pressure hose: Quick release fitting. Electrical Test Lead: Twin flexible lead, terminated with 4 off 4mm gold plated plugs. Electrical probes: 2 off low voltage probes and 2 crocodile clips. Mains power lead.

    Optional Extras

    Pneumatic hand pump, gauges, loop simulators, EasyCal calibration software, spare fuses, and calibration certificates traceable to NPL and UKAS

    Country of Origin UK
  • Models

    7018

    Differential Pressure Calibrator (+ pressure range code shown below)

    Pressure Range Ordering Information
    Range (bar) 0.2 2 5 10

    Range Code

    7100

    7101

    7102

    7103

    Options

    7090

    Pneumatic Hand Pump (-950mbar to 40bar)  -  View web page

    7006

    Loop-Mate 1: Loop Current Simulator  -  View web page

    ECFLA

    EasyCal Full License - when purchased with calibrator/DMM: Discounted full license with 1 year support. 
    For further licenses and EasyCal add-ons see the Easycal web page.

    C178 Factory Calibration Certificate (NPL traceable)
    C190 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    7018 Data Sheet

    424kB

    EN

  • Request for Quotation

    7018 Differential Pressure Calibrator

    Product Options
    1.20

Related Products

  • 7006 Loop Simulator & Source

    • 4 - 20mA or 0 - 10V loops
    • 7 calibration set-points
    • Accuracy 0.1%
    • TxSim and RxTest modes
    • Autostep output - adjustable rate
    • Battery powered PP3
    • Internal loop drive supply
    View 7006
  • 7010 Single Channel Pressure Calibrator

    • Vacuum to 600bar versions
    • Accuracy 0.04% of full scale
    • Pneumatic or hydraulic
    • Over-pressure alarm
    • Isolated 24/36V loop supply
    • Loop current measure
    • Mains / battery power
    View 7010
  • 7015 Dual Channel Pressure Calibrator

    • Vacuum to 600bar versions
    • Accuracy 0.04% of full scale
    • Pneumatic or hydraulic
    • Over- pressure alarm
    • Isolated 24/36V loop supply
    • Loop current measure
    • Mains / battery power
    View 7015
  • 7016 Regulated Low Pressure Calibrator

    • Regulated low pressure
    • Vacuum to 10bar versions
    • Accuracy 0.04% of full scale
    • Pneumatic
    • Isolated 24/36V loop supply
    • Loop current measure
    • Mains / battery power
    View 7016
  • 7095 Handheld Hydraulic Pressure Calibration Pump

    • 0 to 700bar (10,000psi) 
    • Priming feature for fast air purge 
    • Oversized check valve
    • Contoured cushioned handles
    • Built-in pressure relief valve  
    • Hose, fittings, & carry case supplied
    • Optional digital gauge
    View 7095