MENU
UK
  • EN
  • FR
  • ES
Search
Tel: +441732355993

TTS-100 Torque Tester System

TTS-100 Torque Tester
  • TTS-100 Torque Calibration System

Features

  • Calibrate torque wrenches
  • Torque tester unit
  • For use with torque transducers
  • Simple operation
  • Accuracy ± 0.5% of reading
  • Peak, Track, First Peak modes
  • EasyCal Software compatible

TTS-100 Images

  • The TTS-100 is a torque calibration system that offers a solution for torque measurement applications. The torque tester unit provides an easy to use interface that connects to a dedicated torque transducer to perform the calibration of a wide range of torque tools. The system accuracy is ± 0.5% of reading from 10% to 100% of full scale. The tester unit has three operating modes that are Peak, Track and First Peak. It monitors torque and pulse count, and displays both the peak torque and the number of pulses performed during a preset time frame to reach the final torque value.
     
    The accompanying torque transducers are bench mounted calibration instruments designed for the calibration of torque wrenches, torque screwdrivers, and electric & pneumatic screwdrivers. Transducers are available ranging from 1.5 cN.m (2 ozf.in) up to 27,000 N.m (20,000 lbf.ft). Each transducer is bi-directional with a female square drive, and connect to the tester via a port on the side of the unit. Bench mounts are available to provide a firm base for each transducer.
     
    The TE torque calibration system is EasyCal software compatible with connection via USB on the tester unit. Automating the calibration process provides increased speed of calibration and consistency of results. Produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.
     
    Features:
     
    • Calibrate torque wrenches, pulse tools, hand screwdrivers, and power tools
    • Complete solution with torque transducers, mounts and calibration software available
    • System Accuracy ± 0.5% of reading from 10% to 100% of full scale
    • Seven units of torque measurements: (ozf.in, lbf.in, lbf.ft, cN.m, N.m, kgf.m, kgf.cm)
    • Selection of three operation modes: Peak, Track, First Peak
    • Simple operation with easy to use menus and calibration prompts
    • Auto filter frequency selection based upon tool type being used in Peak mode
    • Large easy to read eight digit LCD display
    • Compact, lightweight unit supplied with carry case
    • USB interface and EasyCal calibration software compatible 
  • TTS-100 Torque Tester System

    System Accuracy

    ± 0.5% of reading from 10% to 100% of full scale

    Operating Modes

    Peak, Track, First Peak

    Units of Measure

    ozf.in, lbf.in, lbf.ft, cN.m, N.m, kgf.m, kgf.cm

    OCP Protection

    Over Current Protection (OCP) protects unit from damage or malfunction

    Display

    Eight digit, two line LCD dot matrix display

    Power

    Mains or battery (NimH, charger supplied)

    Battery

    8 hours typical operation. 4 hours typical recharge time.

    Interfaces

    1 x Torque Transducer connection port, 1 x USB port

    Dimensions

    W 148mm x H 118mm x D 48.7mm / 5.8” x 4.63" x 1.92"

    Weight

    0.88kg / 1.94 lbs

    Environmental
    Operating Temperature: 0°C to 50°C
    Storage Temperature: -20°C to 70°C
    Humidity: Maximum of 95% Relative Humidity

    Supplied with

    Carry case, USB cable, rechargeable battery and universal charger

    Options

    Torque Transducers (see below)

    Cable for TE-TRQ transducer to TTS-100 tester

    Mounts for Torque Transducer

     

    Torque Transducers

    TE-TRQ-X20z

    Torque Transducer - 1.5 to 14 cN.m (2 to 20 ozf.in), drive size 1/4 F/Sq

    TE-TRQ-X40z

    Torque Transducer - 2.9 to 28.2 cN.m (4 to 40 ozf.in), drive size 1/4 F/Sq

    TE-TRQ-X80z

    Torque Transducer - 5.7 to 56.5 cN.m (8 to 80 ozf.in), drive size 1/4 F/Sq

    TE-TRQ-X10i

    Torque Transducer - 11.3 to 113 cN.m (1 to 10 lbf.in), drive size 1/4 F/Sq

    TE-TRQ-X25i.

    Torque Transducer - 28.25 to 282.5 cN.m (2 to 25 lbf.in), drive size 1/4 F/Sq

    TE-TRQ-X50i

    Torque Transducer - 56.5 to 565 cN.m (5 to 50 lbf.in), drive size 1/4 F/Sq

    TE-TRQ-X100i

    Torque Transducer - 113 to 1130 cN.m (10 to 100 lbf.in), drive size 1/4 F/Sq

    TE-TRQ-X250i

    Torque Transducer - 282.5 to 2825 cN.m (25 to 250 lbf.in), drive size 1/4 F/Sq

    TE-TRQ-X500i

    Torque Transducer - 565 to 5650 cN.m (50 to 500 lbf.in), drive size 3/8 F/Sq

    TE-TRQ-X750i

    Torque Transducer - 847 to 8473 cN.m (75 to 750 lbf.in), drive size 3/8 F/Sq

    TE-TRQ-X50F

    Torque Transducer - 6.8 to 67.8 N.m (5 to 50 lbf.ft), drive size 3/8 F/Sq

    TE-TRQ-X100F Torque Transducer - 13.56 to 135.6 N.m (10 to 100 lbf.ft), drive size 1/2 F/Sq

    TE-TRQ-X250F

    Torque Transducer - 33.9 to 339 N.m (25 to 250 lbf.ft), drive size 1/2 F/Sq

    TE-TRQ-X500F

    Torque Transducer - 67.8 to 678 N.m (50 to 500 lbf.ft), drive size 3/4 F/Sq

    TE-TRQ-X1000F Torque Transducer - 135.6 to 1355 N.m (100 to 1000 lbf.ft), drive size 1 F/Sq
    TE-TRQ-X2500F Torque Transducer - 339 to 3389 N.m (250 to 2500 lbf.ft), drive size 1 1/2 F/Sq
    TE-TRQ-X5000F Torque Transducer - 678 to 6779 N.m (500 to 5000 lbf.ft), drive size 1 1/2 F/Sq
     TE-TRQ-X10000F Torque Transducer - 1335 to 13558 N.m (1000 to 10000 lbf.ft), drive size 2 1/2 F/Sq
     TE-TRQ-X20000F Torque Transducer - 2711 to 27116 N.m (2000 to 20000 lbf.ft), drive size 2 1/2 F/Sq

    Transducer Specifications:
    Rated Output: 2mv/v Nominal
    Safe Overload: 125% of Rated Output
    Bridge Resistance: 350 Ohms Nominal
    Non linearity: 0.1% of Rated Output
     

    Cables and Mounts

    TE-TRQ-CBL Cable for TE-TRQ transducer to TTS-100
    TE-TRQ-MB-1 Mount for Torque Transducer: For use with TE-TRQX20z - TE-TRQX500F

    TE-TRQ-MB-3

    Mount for Torque Transducer: For use with TE-TRQX1000F - TE-TRQX5000F

  • Models

    TTS-100

    Torque Tester System

    Options

    Transducers

    TE-TRQ-X20z to TE-TRQ-X20000F, see specifications tab for available models

    TE-TRQ-CBL

    Cable for TE-TRQ transducer to TTS-100

    TE-TRQ-MB-1 Mount for Torque Transducer: For use with TE-TRQX20z - TE-TRQX500F
    TE-TRQ-MB-3 Mount for Torque Transducer: For use with TE-TRQX1000F - TE-TRQX5000F
    ECFL EasyCal Calibration Software - Full License
  • PDF Downloads
    File Name File Size Language

    TTS-100 Data Sheet

    433kB

    EN

    EasyCal Brochure

    4MB (low resolution)

    EN

  • Request for Quotation

    TTS-100 Torque Tester System

    Product Options
    1.20

Related Products

  • 7151 Vernier and Micrometer Calibration Kit

    • Calibrate calipers, micrometers
    • Calibrate verniers, depth gauges
    • 47 piece grade 1 block set
    • 300mm gauge block holder
    • Cylindrical jaws
    • 4 optical flats (0-25mm, grade 1)
    • Compact granite surface plate
    View 7151
  • EasyCal Calibration Software

    • Automate the calibration process
    • Control TE calibrators & DMMs
    • Automated planning & scheduling
    • For use with multiple devices
    • 1200+ cal procedures included
    • Management/admin features
    • Easily produce certificates & reports
    View EasyCal