MENU
UK
  • EN
  • FR
  • ES
Search
Tel: +441732355993

1068 Fixed Resistance Box

Resistor Box 1068
  • 1068 Fixed Resistor Box

Features

  • 5 fixed resistance ranges
  • High accuracy
  • Clear visual indication
  • Portable and compact
  • Simple operation
  • Robust casing
  • Ideal for education

1068 Images

  • A compact 5 fixed value resistance box designed for industrial, general laboratory, and education requirements.

    Housed in a robust case the 1068 is easily portable and takes up minimal bench space. Being a low cost and simple operation instrument it is a popular model for physics and electronics laboratories in universities and schools.  

    The high accuracy obtained in the 1068 is achieved by the use of precision resistors. To select a value simply connect test leads to one of the fixed value resistors; 1Ω, 10Ω, 100Ω, 1kΩ, or 10kΩ.

    Connection to the box is via 4mm binding posts and the values are clearly indicated beside each terminal.

  • Technical Specifications

    5 Fixed Ranges 1Ω, 10Ω, 100Ω, 1kΩ, 10kΩ

    Accuracy

    1Ω ± 1mΩ
    10Ω ± 5mΩ
    100Ω ± 10mΩ
    1kΩ ± 100mΩ
    10kΩ ± 1Ω

    Voltage Rating Maximum 250V DC/AC RMS

     
    General Specifications

    Dimensions L115 x W65 x H86mm (including terminals)
    Weight 0.29kg
    Optional Extras Calibration certificates traceable to NPL and UKAS
    Country of Origin UK
  • Models

    1068

    Precision Fixed Resistance Box

    Options
    C164 Factory Calibration Certificate (NPL traceable)
    C114 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    1068 Data Sheet

    178kB

    EN

    1068 User Manual

    112kB

    EN

  • Request for Quotation

    1068 Fixed Resistance Box

    Product Options
    1.20

Related Products

  • 1040 Resistance Decade Box

    • 1Ω to 100MΩ
    • High accuracy
    • Clear visual indication
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1040
  • 1041 Decade Resistance Box

    • 0.01Ω to 1kΩ
    • 10mΩ resolution
    • Ideal for PRT/RTD
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1041
  • 1049 PT100 Simulator

    • -200°C to + 800°C
    • ± 0.3°C accuracy
    • Based on ITS 90 EN60751
    • 23 set points
    • Exceeds class A
    • Good temperature stability
    • Passive resistance source
    View 1049
  • 1051 Resistance Decade Box

    • 0.01Ω to 1MΩ
    • High accuracy & stability
    • Clear visual indication
    • Safety terminals
    • Low temperature coefficient
    • Suitable for PRT/RTD
    • Supplied with protective cover
    View 1051
  • 1061 Resistance Decade Box

    • 1Ω to 1.2MΩ
    • In-line readout
    • Stable metal film resistors
    • Mechanically/electrically robust
    • Ideal for education & electronics
    • Safety terminals
    • Fully screened
    View 1061