MENU
UK
  • EN
  • FR
  • ES
Search
Tel: +441732355993

1065 Power Resistance Decade Box

Power Resistance Box 1065
  • 1065 Power Resistance Decade Box

Features

  • 0.1Ω to 120kΩ
  • 1% accuracy
  • 10W per resistor dissipation
  • Residual resistance < 20mΩ
  • In-line readout
  • Mechanically/electrically robust
  • Fully screened

1065 Images

  • A power resistance decade box designed to meet the standard for industrial use and technical education purposes. Housed in a robust ventilated case, the 1065 can withstand arduous use whilst maintaining accuracy and reliability. 

    The slim line design means it takes up minimum bench space and is easily transportable. The high dissipation of 10 watt per resistor make the 1065 power resistance box suitable for power electronics applications, and the 500V maximum working voltage is ideal for select-on-test use in high voltage circuits.

    Resistance is selected by dialling the value required using the 6 large rotary switches. This enables precise setting with a clear unambiguous indication. Switch contact resistance has been kept to a minimum by the use of multi-wafer switches, each with four parallel, silver-plated, self-cleaning contacts.

  • Technical Specifications

    Range

    0 to 120kΩ

    Number of Decades

    6

    Accuracy

    0.1Ω decade, ± 5%. 1Ω to 120kΩ decades, ±1%.

    Residual Resistance

    Less than 20mΩ

    Power Rating

    10 watt per resistor

    Voltage Rating

    Maximum 500V DC/AC RMS

    Temperature Coefficient

    200ppm/°C

    Resolution 0.1Ω steps


    General Specifications

    Dimensions

    W390 x H80 x D150mm

    Weight

    2kg

    Optional Extras

    Calibration Certificates – traceable to NPL and UKAS

    Country of Origin UK
  • Models

    1065

    Power Resistance Decade Box

    Options

    C161

    Factory Calibration Certificate (NPL traceable)

    C114 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    1065 Data Sheet

    201kB

    EN

    1065 User Manual

    184kB

    EN

  • Request for Quotation

    1065 Power Resistance Decade Box

    Product Options
    1.20

Related Products

  • 1040 Resistance Decade Box

    • 1Ω to 100MΩ
    • High accuracy
    • Clear visual indication
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1040
  • 1041 Decade Resistance Box

    • 0.01Ω to 1kΩ
    • 10mΩ resolution
    • Ideal for PRT/RTD
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1041
  • 1051 Resistance Decade Box

    • 0.01Ω to 1MΩ
    • High accuracy & stability
    • Clear visual indication
    • Safety terminals
    • Low temperature coefficient
    • Suitable for PRT/RTD
    • Supplied with protective cover
    View 1051
  • 1067 Precision Resistance Decade Box

    • 10mΩ to 12kΩ
    • 0.01% accuracy
    • Precision PT100 simulation
    • 6 digit resolution
    • Better than 20ppm/year stability
    • Residual resistance < 10mΩ
    • Fully screened
    View 1067