• EN
  • FR
  • ES
Tel: +441732355993

1061 Resistance Decade Box

Low cost Decade Resistance Box 1061
  • 1061 Resistance Decade Box


  • 1Ω to 1.2MΩ
  • In-line readout
  • Stable metal film resistors
  • Mechanically/electrically robust
  • Ideal for education & electronics
  • Safety terminals
  • Fully screened

1061 Images

  • A low cost resistance decade box designed to meet the standard required in both educational and industrial applications. 

    Metal film resistors with a 0.75 watt power rating are used throughout, providing the advantages of stability and low temperature coefficient. 

    Six large switches with a clear numerical readout make the 1061 resistance box easy to use in educational establishments or in other applications where robustness is a price consideration. The slim line design means it takes up minimum bench space, while the 1% accuracy and wide range makes it suitable for production or select-on-test usage. The case provides complete electrostatic screening. 

    Resistance is selected by dialling the value required using the rotary switches. This enables precise setting with a clear unambiguous indication.

    Safety Terminals
    The front panel safety terminals are compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and spade terminals.

  • Technical Specifications


    0 to 1.2MΩ

    Resolution 1Ω steps

    Number of Decades



    ± 1%

    Residual Resistance

    Less than 150mΩ

    Power Rating

    0.75 watt per resistor

    Voltage Rating

    Maximum 300V DC/AC RMS

    Temperature Coefficient


    General Specifications


    W355 x H63 x D82mm



    Optional Extras

    Calibration Certificates – traceable to NPL and UKAS

    Country of Origin UK
  • Models


    Resistance Decade Box



    Factory Calibration Certificate (NPL traceable)

    C114 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    1061 Data Sheet



    1061 User Manual



  • Request for Quotation

    1061 Resistance Decade Box

    Product Options

Related Products

  • 1040 Resistance Decade Box

    • 1Ω to 100MΩ
    • High accuracy
    • Clear visual indication
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1040
  • 1041 Decade Resistance Box

    • 0.01Ω to 1kΩ
    • 10mΩ resolution
    • Ideal for PRT/RTD
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1041
  • 1051 Resistance Decade Box

    • 0.01Ω to 1MΩ
    • High accuracy & stability
    • Clear visual indication
    • Safety terminals
    • Low temperature coefficient
    • Suitable for PRT/RTD
    • Supplied with protective cover
    View 1051
  • 1065 Power Resistance Decade Box

    • 0.1Ω to 120kΩ
    • 1% accuracy
    • 10W per resistor dissipation
    • Residual resistance < 20mΩ
    • In-line readout
    • Mechanically/electrically robust
    • Fully screened
    View 1065