1041 Decade Resistance Box

1041 Resistance Substitution Box
  • 1041 Decade Resistance Box


  • 0.01Ω to 1kΩ
  • 10mΩ resolution
  • Ideal for PRT/RTD
  • High stability
  • Safety terminals
  • Low temperature coefficient
  • Supplied with protective cover

1041 Images

  • A precision low ohm resistance box designed for general laboratory work including platinum resistance thermometry.

    The 1041 decade box is compact and durable, housed in a robust metal case with removable protective rubber cover, making it ideal for use in either the laboratory or field. Excellent accuracy is achieved by using high stability metal film resistors. The 5-digit thumbwheel switch enables simple and precise setting with a clear indication of the resistance value.

    Switch Contacts
    Special attention has been given to the reliability of operation. A special multiple gold contact arrangement ensures low contact resistance and continued operation even if a contact fails.

    Clear Visual Indication
    To make selecting and reading the setting easy the 1041 incorporates colour coded digits: ohms - white, milliohms - yellow.

    Safety Terminals
    Compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and spade terminals.

    Added Protection
    The 1041 comes fitted with an ergonomic rubber cover providing increased protection and durability. It has a textured grip for comfortable handling and side openings to place labels. It is easy to remove if the user prefers a stand-alone unit or to house the 1041 in the optional 9026 carry case.

    This low ohm resistance box is part of the Time Electronics well-proven decade box line. It can be used as a calibration standard for site and workshop use and is ideal for PT100 and other resistance input instrumentation. 

  • Technical Specifications


    0 to 1kΩ

    Resolution 0.01Ω steps
    Decade 0.01Ω 0.1Ω 10Ω 100Ω
    Accuracy ± 10% ± 5% ± 1% ± 0.5% ± 0.1%
    Max Current 1A 1A 1A 0.3A 0.1A
    Residual Resistance Less than 60mΩ
    Power Rating 1 watt per resistor
    Voltage Rating Maximum 100V DC/AC RMS
    Temperature Coefficient 50ppm/°C

    General Specifications

    Dimensions W215 x H100 x D120mm including protective cover (W200 x H75 x D110mm without)
    Weight 1kg including protective cover (0.6kg without)
    Supplied With Protective cover (fitted) and user manual
    Optional Extras Leather carry case. Calibration certificates traceable NPL and UKAS
    Country of Origin UK
  • Models


    Low Ohm Resistance Decade Box

    9026 Leatherette Carry Case
    C161 Factory Calibration Certificate (NPL)
    C114 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    1041 Data Sheet



    1041 User Manual



    Carry Case Option Data Sheet 726kB EN
  • Request for Quotation

    1041 Decade Resistance Box

    Product Options

Related Products

  • 1040 Resistance Decade Box

    • 1Ω to 100MΩ
    • High accuracy
    • Clear visual indication
    • High stability
    • Safety terminals
    • Low temperature coefficient
    • Supplied with protective cover
    View 1040
  • 1051 Resistance Decade Box

    • 0.01Ω to 1MΩ
    • High accuracy & stability
    • Clear visual indication
    • Safety terminals
    • Low temperature coefficient
    • Suitable for PRT/RTD
    • Supplied with protective cover
    View 1051
  • 1061 Resistance Decade Box

    • 1Ω to 1.2MΩ
    • In-line readout
    • Stable metal film resistors
    • Mechanically/electrically robust
    • Ideal for education & electronics
    • Safety terminals
    • Fully screened
    View 1061
  • 1067 Precision Resistance Decade Box

    • 10mΩ to 12kΩ
    • 0.01% accuracy
    • Precision PT100 simulation
    • 6 digit resolution
    • Better than 20ppm/year stability
    • Residual resistance < 10mΩ
    • Fully screened