MENU
UK
  • EN
  • FR
  • ES
Search
Tel: +441732355993

7053 Precision Adjustable DC Power Supply

  • Precision DC Power Supply
    A DC linear power supply with high accuracy, resolution, stability and noise. Multiple output ranges provide increased current capability at lower voltages. An advanced user interface gives superior control, combining speed with safety.Voltage and current are controlled using instrumentation quality 16 bit DACs enabling voltages to be set to 1mV resolution even at full output. The accuracy is sufficient for the 7053 to be used as a calibration source for some hand-held DMMs.

    Fast, simple, and safe to use
    The user interface of the 7053 has been designed to provide rapid control whilst guarding against any possibility of error. The 7053 provides both numeric and rotary control. Illuminated keys and display legends provide instant confirmation of settings and status. Voltage and current setting can be performed in 2 ways.

    Direct numeric entry: Settings can be made by direct numeric entry using the 0 to 9 keypad. Each new setting is previewed on the display and must be confirmed with the OK key. Settings recalled from memory are similarly previewed and confirmed. Numeric setting is very fast requiring only three key presses to set to 5 volts, for example, (V, 5, OK). To set a more precise level such as 12.725 volts requires more key presses, but can still be done in seconds.

    Incremental rotary control: For those preferring quasi-analogue control, or for applications where the voltage or current must be gradually changed, the jog wheel is available. The wheel has a positive stepped action but can be spun rapidly when required. Output voltage can be incremented or decremented in steps of 0.1V, 10mV or 1mV. Current steps can be selected from 0.1A down to 0.1mA. The Jog function can be left permanently engaged or can be disabled at the touch of a button.

    Instant Limits view: The 7053's has storage of up to 10 power supply sets-up in non-volatile memory. Upon mains switch-off, the set-up of the 7053 is saved and is automatically restored at switch-on.

    Flexibility
    Switchable between the 3 ranges provides a higher current capability at lower voltages and increased current resolution when needed.

    Low Noise
    True linear regulation with output ripple and noise below 0.35 mV in CV mode and down to 20μA in CI mode. Regulation near the limit of measurement. Fast control loop giving exceptional dynamic performance and recovery.

    Protection
    The 7053 provides fully adjustable over-voltage and over-current trips which can be used both as a fail-safe against accidental mis-setting and as a protection against inappropriate load conditions. In addition to turning the output off, a trip condition switches the rear panel alarm signal enabling other equipment to be controlled. For complete protection of the power supply, the trip will also be operated by over-temperature or excess voltage on the sense terminals.

    Programmable Version
    The 7053P programmbale version enables full remote control via GPIB (IEEE-488), RS-232 or USB interfaces.

  • Technical Specifications

    Main Output
    Max. Output Power 112 watts
    Output Ranges Range 1 - 0 to 56V, 0 to 2A Range 2 - 0 to 25V, 0 to 4A. Range 3 - 0 to 56V, 0 to 500.0mA
    Voltage Setting By floating point numeric entry or rotary jog wheel; resolution 1mV
    Current Setting By floating point numeric entry or rotary jog wheel; resolution 1mA or 0.1mA depending on range.
    Setting Accuracy Voltage - 0.03% ±5mV. Current 0.2% ±5mA/0.5mA
    Output Mode Operation in constant voltage or current modes with automatic cross-over and mode indication by LEDs.
    DC Output Switch Sets output voltage and current levels to zero when Off.
    Output Terminals 4mm terminals on 19mm (0.75”) spacing.
    Load Regulation <0.01% of maximum output for 50% load change.
    Line Regulation <0.01% of maximum output for 10% line voltage change.
    Ripple and Noise Typically <0.35mV rms.
    Transient Response <20usec to within 15mV of setting for 90% load change.
    Temp Coefficient < ±(50ppm+0.5mV)/°C (voltage)
    Remote Sense Eliminates up to 0.5V drop per lead. This operation is selected from front panel and indicated by LED.
    Sense Terminals Recessed sprung sockets for direct insertion of wires.
    Output Protection
    Fault Condition Trip The output will be shut down if any of the four trip conditions listed below occur.
    Over Voltage (OVP) Settable 1V to 62V in 0.1V steps.
    Over Current (OCP) Settable 0.1A to 4.4A in 0.01A steps.
    Over Temperature Monitors internal temperature rise to protect against excess ambient temperature or blocked ventilation slots
    Sense Error Monitors the voltage between the remote sense terminals and output terminals to protect against mis-wiring.

    Output will withstand forward voltages of up to 20V above rated output voltage. Reverse protection by diode clamp for currents up to 3A. 

    Metering
    Display Type Dual digital meters per output using 14mm (0.56”) high brightness LEDs. 5 digit voltmeter, 4 digit current meter. Reading rate 4 per second.
    Meter Function Voltage meter shows set voltage when in CV mode and measured voltage when in CI mode. Current meter shows measured current when in CV mode and set current when in CI mode.
    Limits Display With the dc output switch set to Off, both meters show the set values (i.e. the limits). With the output on, either the voltage meter or current meter will show a measured value (depending on the CV/CI mode). Pressing the Limits button will provide a temporary display of the set values.
    Watts (VxA) Display The voltage meter can be made to show the instantaneous calculated product of voltage and current. The value displayed is equal to the equivalent power at the moment when the button is pressed and remains whilst the button is held.
    Meter Resolution Voltage: 1mV (CV mode) or 10mV (CI mode). Current: 1mA or 0.1mA depending on range. Power: 0.01W or 0.001W depending on range.
    Meter Accuracy Voltage: 0.05% of reading ±10 mV (CI mode). Current: 0.2% of reading ± 0.005A or 0.5mA (CV mode). Power: 0.3% of reading ± 0.05W or 0.005W
    Setting Memories
    Number of Stores 10 plus power-down store.

    Memory Type

    Non-volatile using EEPROM. 

    Parameters Stored Range, Set volts, Set current, OVP, OCP.
    Recall System Settings are previewed onto the displays before being actioned.


    General Specifications

    Power Requirements 230V or 115V. Installation category 11. Power is dependant on the line power to the calibration bench.
    Operating Range 5°C to 40°C, 20% to 80% RH. Storage Range: -20°C to +60°C

    Module Width

    180mm (primary console fitting only)

    Programmable Version 7053P: RS-232 or USB, connection via the rear of the bench console.
  • PDF Downloads
    File Name File Size Language

    7053 Data Sheet

    399kB

    EN

    CalBench Brochure

    8.4MB (Low resolution)

    EN

    CalBench Brochure

    20MB (Higher resolution)

    EN