7046 & 7047 Variable AC/DC Power Supply Modules

  • The 7046 and 7047 are primarily variable AC power supply modules with the capability to provide DC power also. Both modules are highly versatile and incorporate various functions and features for increased usability.

    Performance and Features 

    Output characteristics: AC mode
    The output voltage varies from 1 V to 135 V or 2 V to 270 V (two ranges). You can switch ranges manually or automatically. The peak current can triple the maximum rated current for the rectifier load of the capacitor input type. The frequency varies from 40 Hz to 500 Hz.

    Output characteristics: DC mode
    The output voltage varies from ±1.4 V to 190 V or ±2.8 V to 380 V (two ranges). You can switch ranges manually or automatically. The maximum instantaneous current is up to three times higher than the maximum rated current.

    Input characteristics
    The input voltage is from 100 V AC to 120 V AC or 200 V AC to 240 V AC at 50 Hz/60 Hz (single phase). The voltage is automatically determined when the power supply is turned on.

    Measurement functions
    The 7046 and 7047 can measure the voltage, current, and power of AC and DC output. They can display the true RMS and the average (DC) values for the output voltage, and the true RMS, peak and the average (DC) values for the output current.

    Protection
    The following protection features are available:
    • Protection against non-rated input voltage
    • Protection against overheat (OHP)
    • Protection against overload: Current limit (OCP)/monitoring for exceeded power (OPP)/monitoring for exceeded peak current
    • Detection of voltage abnormalities: Increased voltage (OVP)/decreased voltage (LVP)

    Output on phase angle
    The output on phase angle can be set at AC mode. The output off phase angle is turned off at a zero cross phase.

    Memory function
    The 7046 and 7047 can store three sets of setting value for output voltage and frequency, and limit value. By manually changing the preset memory during output, the test for sudden changes of voltage and frequency is also possible.

  • Module Output Voltage AC Output Current AC Output Frequency Output Voltage DC Output Current DC Setting Resolution

    7046

    1 to 270V AC

    5A

    40-500Hz

    1.4 to ±380

    4A

    0.1 V

    7047

    1 to 270V AC

    10A

    40-500Hz

    1.4 to ±380

    8A

    0.1 V

    Module Width

    7046: 295mm / 7047: 500mm (must be fitted in the primary console)

    Full specifications and details upon request.