5033 3 Channel DC Power Source

5033 3 Channel DC Power Source
  • 5033 3 Channel DC Power Source

Features

  • 3 independent channels
  • 0 to 20V DC 2A drive capability
  • 40 watts max per channel
  • 10μV resolution setting
  • Programmable via GPIB interface
  • Easy to use command language
  • 4 Terminal Output

5033 Images

  • The 5033 provides 3 independent channels of 0 to 20V DC, settable in 10µV steps. A 2A drive capability allows up to 40W per channel to be output. A precision current shunt is incorporated in each channel and allows read-back of the current supplied.

    The high resolution on the voltage and current make this power source ideal for calorimetry and other applications requiring very accurate control of DC power input. Power can be controlled to better than a few ppm.

    The excellent resolutions for the voltage output and current readback are matched by stability performance that allows test runs of 24hrs or more and still maintain precision. The voltage output is stable to better than 2ppm per 24hrs at full load and the basic temperature coefficient is better than 1ppm/°C. Measurement of the current is done by using a precision shunt.

    Full 4 terminal operation is provided to compensate for volt drops in connection leads. Front panel indicators provide the user with clear indications of data transfer and also show when errors have occurred or invalid commands have been issued.

    The instrument is constructed in a standard 19” Euro case and is suitable for rack or bench use. All connections are at the rear of the unit.

  • Technical Specifications

    Number of Channels 3 - fully floating
    Output Voltage 0 to 20V DC
    Output Current 2A maximum. Programmable limit, 10mA to 2A in 10mA steps
    Output Power 40W maximum per channel
    Output Terminals 2 wire or 4 wire. low thermal emf construction
    Setting Resolution 22 bits (0.25ppm)
    Accuracy 20ppm of output + 400μV
    Linearity < 10ppm of full scale
    Output Resistance < 1mΩ
    Stability < 2ppm/24hrs, < 5ppm/month, < 15ppm/year
    Noise level < 1ppm at 1Hz and lower
    Temp Coefficient < 1ppm/°C
    Front Panel Display For each channel, ‘Error’, ‘Data transfer’, ‘Power’
    Fuses Mains input power, Channel input power 3 x 3A slow blow
    Current read-back 0.1Ω internal precision


    General Specifications

    Interface / Protocol GPIB / SCPI command language
    Mains Power 115V/230V (+/-5%), 50/60Hz
    Construction 19” 3U Rack mount frame.
    Dimensions 483 x 331 x 134mm
    Weight 14kg
    Country of Origin UK
  • Models

    5033

    3 Channel Programmable DC Power Source

    Options
    C169 Factory Calibration Certificate (NPL traceable)
    C116 UKAS Calibration Certificate (ISO 17025)
  • PDF Downloads
    File Name File Size Language

    5033 Data Sheet

    181kB

    EN

  • Request for Quotation

    5033 3 Channel DC Power Source

    Product Options
    1.20

Related Products

  • 5018 Programmable DC/AC V/I Calibrator

    • 0 - 22V DCV (30V DC optional)
    • 0 - 22V AC, 220V & 1kV DC options
    • Optional 0 - 220mA AC/DC
    • Ramping feature
    • GPIB / RS-232 / USB interfaces
    • Ideal for ATE applications
    • EasyCal Software compatible
    View 5018
  • 5025C Multifunction Calibrator

    • 15ppm precision calibrator
    • Calibrate up to 6.5 digit meters
    • 11 standard functions 
    • 0 - 1050V & 0 - 22A (AC/DC)
    • Resistance & capacitance
    • Thermocouple/PT100 simulation
    • Oscilloscope & power options
    View 5025C
  • 5075 7.5 digit Multimeter

    • 7½ digit resolution
    • AC/DC voltage & current
    • Resistance & temperature
    • Capacitance & frequency
    • 18ppm/year accuracy
    • 10 channel scanner option
    • EasyCal software compatible
    View 5075
  • 5077 Power Calibrator

    • 20mA to 22A AC/DC
    • 100A AC I transformer option
    • 1mV to 1050V AC/DC
    • +90.0 deg to -90.0 deg
    • 0.00 to 1.00 Lead/Lag
    • 45 to 400 Hz in 0.1Hz steps
    • RS-232 / GPIB / USB interface
    View 5077