Mains Power is controlled via a
7082
single-phase unit equipped with 2 mains power sockets (types
selectable). A further 4 sockets come supplied on the underside
of the console. A main power switch, residual current circuit
breaker with over-current protection (RCBO), and under console
lighting switch are included. Mains input and lighting supply
lines are filtered.
The mains voltage is continuously monitored on a digital meter.
The two front panel sockets can be supplied via an isolation
transformer as an optional extra. With this fitted the total
current from the two sockets is limited to 1A. Another additional
option is a 110V DC 5A supply with circuit breaker.
Available fittings include UK 13A, Euro Shuko 16A, US
15A, and Indian
Round Pin 15A.
| Specification |
| Switches |
Mains
power on/off switch to provide isolation for the entire
bench.
Lighting switch to provide separate control of the work-top
lighting. |
| Protection |
16A
overload protection for entire bench. Residual current
protection is 0.03A.
5amp circuit breaker is fitted for the unregulated 110
volt DC supply option. |
| Sockets |
2
x console front panel earthed sockets, 4 x console underside
earthed sockets.
2 x 4mm front panel shrouded sockets for the 110-volt
DC supply option. |
| Meters |
Mains
voltage (0-300V) |
| Filter |
2
filters fitted to attenuate mains spikes |
| Panel
size |
Width
273 x height 201mm |
| Cooling |
2
x Mains powered 80mm cooling fans are fitted internally
to the console. |
| Earthing |
A
PE socket is provided. All metal parts of the bench
are connected to mains earth. |
| Options |
7063 |
Isolated
mains power up to 1 Amp, from the two front sockets.
A 1 Amp cartridge fuse protects the supply. |
7075 |
110
volts DC up to 5 Amps. The supply is via two front panel
mounted shrouded sockets and is protected by a resettable
5 Amp circuit breaker, this also acts as a independent
110V power switch. |