Features:

 

Accuracy 0.01% of reading

 

Resolution 0.001 mA
  24 Volt Supply
  √ User Functions for Flow
  2/3 Wire Operation
  Manual Adjustment
  Set Points, Programmable Ramp
  Battery Management
  4 Wire connections for READ and SIMULATE
Description:

The 7005 is a micro-processor based handheld process control instrument for voltage and current loop calibration and simulation. It can operate in three modes:
a) Loop current/voltage Source (transmitter simulation and loop supply simulation)
b) Sink of loop current (transmitter simulation)
c) Measurement of loop current/voltage (loop indicator simulation).

Manual step of the output is available at five calibration points, 0%, 25%, 50%, 75% and 100% of span. Automatic stepping of the output is also available both up and down with programmable dwell times.

Continuous up/down ramping is also available with user programmable ramp rates and dwell time (top and bottom).

In source mode the range can be user programmed to any value between 0mA and 50mA, or 0V and 21V. For example a low point of 10mA and a high point of 50mA could be set giving a span of 40mA

Measure mode provides both voltage and current measuring capability with 5 digit resolution. Ranges are 0 to ±5V and ±5 to ±25V, 0 to ±25mA and ±25 to ±125mA. Alternatively the signal can be measured as a % of span for the following ranges, 4 to 20mA, 0 to 20mA, square root 4 to 20mA, square root 0 to 20mA. For all measurements a Min/Max recording function is available on demand.

An internal NiCad battery can power the unit for typically 9 hours and an external mains charger is supplied as standard. An automatic power-down feature is incorporated to conserve battery life.

This process calibrator is one of Time Electronics' comprehensive process control equipment line. With source and measure capabilities it delivers accuracy and reliability in one instrument.

 
 