The 5051 is a high performance calibrator combining both source and measure functions and can calibrate bench and handheld multi-meters, frequency meters, ohm meters, ac/dc millivoltmeters, thermocouple indicators and more

5051 Multifunction Calibration System

Click to view EasyCal Software page

Features:

 

0 - 1kV AC/DC

 

0 - 20A AC/DC

 

0.1Hz - 10MHz Frequency

 

1R - 1GR Resistance
  Thermocouple simulation
  Clamp Meter Calibration
  Industrial quality internal PC
Description:

Functionality and Flexibility:
The 5051 Multifunction Calibration System combines a high accuracy calibration source with a precision digital multimeter (DMM).

It provides a wide range of calibrated outputs for AC/DC Voltage up to 1000V, AC / DC current to 20 amps, plus a range of resistance, capacitance, inductance and frequency. An option for calibrating oscilloscopes is also available. The DMM section can measure DC voltages to 1000V, AC voltages to 750V, and resistance to 100Mohms.

The 5051 can calibrate, bench and handheld multi-meters, frequency meters, ohm meters, ac/dc millivoltmeters, thermocouple indicators, resistance boxes, clamp meters, temperature indicators/sensors, RTDs, power supplies, signal generators, ac/dc signal sources, timer counters, oscilloscopes and much, much more.

Reliability and Accuracy:
It’s outstanding performance is based on Time Electronics own 22 bit Digital to Analogue converter which provides 0.25ppm resolution. The linearity and temperature coefficients are compensated by patented software techniques to provide better than 0.05ppm/degC.
Precise calibration is possible using the deviation function - this provides a direct error readout for the instrument being calibrated.

Ease of use:
The control software allows a wide range of functions to be selected using mouse, keyboard, or touch screen. In addition Time Electronics’ well established EasyCal software provides a straightforward and user friendly automatic calibration environment.
 
Ordering Information
Code
Multifunction Calibrator
5051
Options
DMM 6.5 digit (AC/DC 1kV/3A, 0-100M ohm resistance, 300kHz freq.)
9791
Touch Screen
9793
Printer and Connectivity kit
9795
Capacitance (1000pF- 100uF) / Inductance (1mH - 10H)
9798
Simulated Resistance (10 ohm - 40 Mohm)
9774
High Frequency AC Voltage (1MHz Max. 20mV - 20V)
9771
Scope Calibration (1mV to 200V, 0.1Hz - 100 MHz, < 1nS risetime)
9770
Scope/Timer Calibration (1mV to 200V,0.1Hz - 400MHz, Levelled Sine, < 1nS rise)
9775
Scope 2.2GHz Levelled Sine Generator (Internal)
9769
Rubidium High Stability Frequency Reference (External - scope options only)
9762
Oven-Controlled High Stability Frequency Reference (Internal - scope options only)
9783
External Low Noise Attenuator 1000:1
9766
External Low Noise Attenuator 100:1
9767
Power Calibration (0-20KW AC and DC) option (external) - view 5077 web page
5077
Optical Tacho Adaptor - view separate datasheet
9773
Clamp Meter Adaptor (1 and 50 turn coils) - view web 9780 web page
9780
100 Amp AC Current Transformer - view separate datasheet
9790
Power Amplifier - view separate datasheet
9760
Carry Muff - view 9082 web page
9082
Test Lead Set - view 9796 web page
9796
Remote Pressure Module- view 7042 web page
7042
EasyCal Software - view EasyCal web page
9747
Crystal Reports
9329
EasyCal - Additional Users
9736
Bar Code Reader
9777
Cal and ID Label Printer
9778
Job Card and Address Label Printer
9779
GPIB Interface Card (PCI)
9743
USB-GPIB adaptor
9794
GPIB cable
9597
5051PLUS Complete Calibration System (Special Package Price): 9791 DMM; 9770 Scope 100MHz; 9798 Cap & Ind; 9774 Sim Res; 9795 Printer & Con Kit; 9796 Test Lead Set; 9747 Easy Cal; 9780 Clamp Meter Adaptor; 9329 Crystal Reports; 9793 Touch Screen; 9165 NPL Cert; 9082 Carry Muff. (For additional options see above)
5051+
Printable Version of this page
ENLARGE IMAGE Download Datasheet DOWNLOAD DATASHEET REQUEST A 5051 PRICE QUOTE ONLINE
9082 Carry Case
9796 Test Lead Kit
Easycal Calibration Software
9780 Clamp Meter Adaptor