Full Catalogue
Portable Test Instruments
Decade Boxes
Multifunction Calibrators
Programmable Instruments
Process Control Equipment
Calibration Benches
Calibration Software
Accessories
 
Physical

Electrical

 
5051 Multifunction Calibrator
EasyCal Software
1051 Decade Box
TE Calibration Bench
5077 Power Calibrator
5075 Precision DMM
7090 Pneumatic Cal. Pump
1044 Portable DC V/I Cal.
The 5025 can calibrate bench and handheld multi-meters, frequency meters, ohm meters, ac/dc millivoltmeters, thermocouple indicators, clamp meters, temperature indicators, timer counters, oscilloscopes and many other measurement devices

5025 Multifunction Calibrator

Click to view EasyCal Software page

Features:

0 - 1050 V AC/DC voltage

0 - 22 A AC/DC current

0 - 1Gohm resistance

Thermocouple simulation
  Digital Frequency
  Oscilloscope Calibration
  PT100 simulation
  Capacitance & Inductance
  Power & Clamp Meter Calibration
   GPIB, RS232 & USB Interface
  Shuttle knob deviation
Description:

Multi Instrument Calibration
A calibrator with a wide range of capabilities to cover multiple functions is a modern day necessity. The 5025 is the ultimate multi-product calibrator, designed for both traditional and new measurement equipment.
The 5025 can calibrate, bench and handheld multi-meters, frequency meters, ohm meters, ac/dc millivoltmeters, thermocouple indicators, clamp meters, temperature indicators, timer counters, oscilloscopes and many other measurement devices.

Simple Operation
Functions and ranges are easily accessed from the front panel. Increase and decrease keys per digit, are used to quickly set the output value. Deviation control then enables the user to finely adjust the output value as a percentage (+/-9.999%). All this information is shown on a clear, easy to read LED display.

Flexible Options
The 5025 can be equipped to specific requirements. The standard unit is fitted with AC/DC voltage to 1050kV, AC/DC current to 22A, digital frequency to 10MHz, decade resistance to 1G ohms, conductance and thermocouple simulation.
Individual options include; capacitance and inductance, full range resistance (incorporating PT100 simulation), power calibration and oscilloscope calibration. These options can be specified at time of order or fitted at a later date by an authorised service agent.
In addition external adaptors are available for clamp meter calibration (up to 1000A), optical tachometer calibration and low noise attenuation.

Calibration Made Easy
Connect the 5025 to a PC/Laptop (via RS233, GPIB or USB) installed with Time Electronics EasyCal and automate the calibration process. Increase speed of calibration and consistency of results, produce calibration certificates and reports to ISO 9001 quality standards.

 
Ordering Information
Code
Multifunction Calibrator
5025
Options
Capacitance (1000pF- 100uF) / Inductance (1mH - 10H)
9798
Simulated Resistance (10 ohm - 40 Mohm)
9774
Full Range Resistance (1 ohm - 120 Mohm)
9787
High Frequency AC Voltage (1MHz Max. 20mV - 20V)
9771
Scope Calibration (1mV to 200V, 0.1Hz - 100 MHz, < 1nS risetime)
9770
Scope 2.2GHz Levelled Sine Generator (RS232/GPIB) (External) - view datasheet
9769
Rubidium High Stability Frequency Reference (External - scope options only)
9762
Oven-Controlled High Stability Frequency Reference (Internal - scope options only)
9783
External Low Noise Attenuator 1000:1
9766
External Low Noise Attenuator 100:1
9767
Power Calibration (0 - 20KW AC and DC)
9797
Clamp Meter Adaptor (1 and 50 turn coils) - view web 9780 web page
9780
Optical Tacho Adaptor - view separate datasheet
9773
100 Amp AC Current Transformer - view separate datasheet
9790
Carry Muff - view web 9085 web page
9085
Rack mount kit
9724
Test Lead Set - view 9541 web page
9541
EasyCal Software - view EasyCal web page
9747
Crystal Reports
9329
EasyCal - Additional Users
9736
Bar Code Reader
9777
Cal and ID Label Printer
9778
Job Card and Address Label Printer
9779
GPIB Interface Card (PCI)
9743
USB-GPIB adaptor
9794
GPIB cable
9597
RS232 Cable
9588
USB Interface for control of 5025
9765
Printable Version of this page
ENLARGE IMAGE Download Datasheet DOWNLOAD DATASHEET REQUEST A 5025 PRICE QUOTE ONLINE
9085 Carry Case
9541 Test Lead Kit 
9765 USB Interface
Easycal Calibration Software