Full Catalogue
Portable Test Instruments
Decade Boxes
Multifunction Calibrators
Programmable Instruments
Process Control Equipment
Calibration Benches
Calibration Software
Accessories
 
Physical
Electrical
 
5025 Multifunction Calibrator
EasyCal Software
1051 Resistance Decade Box
TE Calibration Bench
5077 Power Calibrator
5018 DC/AC V/I Calibrator
1065 Power Resistance Box
1048 V/I Loop Calibrator
5025 Multifunction Calibrator with Power Option
Multi Product Calibration Package

Multi Product Calibration System - Discount Package

            • 5025 Multifunction Calibrator
            • 5065 6.5 Digit Bench Multimeter
            • EasyCal Calibration Software
            • 9780 Clamp Meter Adaptor
            • 9541 5 Piece Test Lead Set
            • 9765 USB Interface for 5025
            • 9778 Calibration & ID Label Printer
            • Factory (NPL) Calibration Certificates for 5025 and 5065

Time Electronics have released a Multifunction Calibrator/DMM/Software package for the cost effective solution to multi-instrument calibration. In-house calibration has become affordable and easy to implement, with benefits of cutting costs and improving efficiency. This comprehensive package enables companies to get started immediately.

The 5025 can calibrate, bench and handheld multi-meters, frequency meters, ohm meters, ac/dc millivoltmeters, thermocouple indicators, clamp meters, temperature indicators, timer counters, oscilloscopes and many other measurement devices.

The standard unit is fitted with AC/DC voltage to 1050kV, AC/DC current to 22A, digital frequency to 10MHz, decade resistance to 1G ohms, and thermocouple simulation.

Optional extras include; capacitance and inductance, full range resistance (incorporating PT100 simulation), power calibration and oscilloscope calibration.

The 5065 DMM is a versatile, highly accurate, 6 ½ digit multimeter measuring AC/DC voltage and current, resistance, thermocouples, RTDs, frequency and period.

In addition to standard functions many other capabilities such as Min/Max, Ratio/% and Null are included. Memory functions with up to 2000 readings can be stored and recalled. Limit testing with an external output can be configured to signal pass or fail.

Both the 5025 and 5065 integrate with EasyCal to automate the calibration process. Increase speed of calibration and consistency of results, and produce calibration certificates and reports.

Also included is a clamp meter adaptor, test lead set, USB interface for 5025, calibration label & ID printer, and factory calibration certificates for the 5025 and 5065 (traceable to NPL). Further options can be added as required.

5025 DMM/EASYCAL Package datasheet (223KB)

Request an Online Price Quote for this package

View 5025 web page
View EasyCal web page
View 5065 web page