Full Catalogue
Portable Test Instruments
Decade Boxes
Multifunction Calibrators
Programmable Instruments
Process Control Equipment
Calibration Benches
Calibration Software
Accessories
 
Physical
Electrical
 
5051 Multifunction Calibrator
EasyCal Software
1051 Decade Box
TE Calibration Bench
5077 Power Calibrator
5075 Precision DMM
7090 Pneumatic Cal. Pump
1044 Portable DC V/I Cal.
5018 High Accuracy and Stability Programmable DC/AC Voltage / Current Calibrator

5018 Programmable DC/AC Voltage / Current Calibrator

Click to view EasyCal Software page

Features:

 

1999999 full scale + 10% over-range

 

20mV-200mV-2V-20V DC voltage

 

Deviation control -9.999% to +9.999%
  GPIB,RS232, & USB interface
  Ideal for ATE application
Options:
  20uA-200uA-2mA-20mA-200mA DC
  AC Voltage and Current
  200V and 1050V DC/AC range
  19" Rack Mount Kit
Description:

The outstanding accuracy and stability of the 5018 is achieved by the use of a patented circuit. It incorporates a dedicated micro-processor to continually monitor the state of a bank of precision voltage references. The basic digital to analogue converter has 22 bit (0.25ppm) resolution. Linearity and temperature coefficient are compensated in software to better than 0.1ppm of full scale per °C. For the DC 2V/20V ranges short term stability is <0.5ppm/day and <2ppm/month. An external 1000:1 screened attenuator is available as an option for very low noise AC output.

Display
Simple front panel operation allows the user to quickly set the function and output required.
Using the jog / shuttle dial deviation the user can finely adjust the output value as a percentage (+/-99.99%). All this information is shown on a clear, easy to read LED display.

GPIB, RS232 & USB Interface
These interfaces allow the 5018 to be connected to a PC and controlled by an external program such as Time Electronics’ EasyCal calibration software. The 5018 uses a SCPI command structure for programming. This makes writing control programs in Visual Basic, C and Labview a simple task.

Ramping Feature
The 5018 includes an internal ramping feature. A ramp rate per range for each function can be set. The option to ramp the output can be turned on or off via the front panel.

Calibration Made Easy
Connect the 5018 to a PC/Laptop (via RS232, GPIB or USB) installed with Time Electronics EasyCal and automate the calibration process. Increase speed of calibration and consistency of results; produce calibration certificates and reports to ISO 9001 quality standards. EasyCal has the ability to control a wide range of programmable instruments and comprehensive ATE systems can be configured to control a variety of applications. It has full read back capability and therefore can perform closed loop testing. Conditional tests can be configured to allow decision making to further enhance the usefulness.

 
 
Printable Version of this page
ENLARGE IMAGE Download Datasheet DOWNLOAD DATASHEET REQUEST A 5018 PRICE QUOTE ONLINE
EasyCal Calibration Software
9765 USB Interface
5025 Multifunction Calibrator
5011 Res/Temp Calibrator