Full Catalogue
Portable Test Instruments
Decade Boxes
Multifunction Calibrators
Programmable Instruments
Process Control Equipment
Calibration Benches
Calibration Software
Accessories
 
Physical
Electrical
 
5025 Multifunction Calibrator
EasyCal Software
1051 Resistance Decade Box
TE Calibration Bench
5077 Power Calibrator
5018 DC/AC V/I Calibrator
1065 Power Resistance Box
1048 V/I Loop Calibrator
1090 Portable Temperature Calibrator that combines source and measurement functions for thermocouples, PT100s, uV, mV, and mA
1090 Portable Temperature and Process Calibrator
Features:

 

Measure/Simulate 8 thermocouple types, PT100-RTD, mV, and mA

 

Displays units in °C/°F, uV/mV, or mA

 

Large super twist LCD display

 

Sealed membrane keypad
  Auto or manual cold junction compensation
  Carry case with test lead compartment
  Inching & Step functions
  Rechargeable battery power, 60+ hours use
Description:

The 1090 is a high performance, simple key press operation, portable instrument combining source and measurement functions for thermocouples, RTDs, mV and mA. Powered by 6 internal AA size batteries. The rechargeable version of these batteries are supplied in the instrument as standard, along with a mains re-charger. The batteries can be recharged without removing them from the instrument.

Thermocouple measurement and simulation: The 1090 can verify and simulate the temperature/mV characteristics of a wide range of thermocouples to an accuracy of better than 0.05%.

Cold Junction Compensation: Automatic cold junction compensation is included for ease of use with a manual over-ride.

RTD, mV, and mA measurement and generation: In addition to thermocouple simulation, the 1090 can also be used for measurement and simulation of PT100-RTD, plus measurement and generation of mV and mA.

Inching: Increment and decrement keys enable the output to be ‘inched’ up or down in 0.1, 1 or 10 degC (menu settable) steps or temperatures. 1, 10, or 100uV steps are also available for voltage output. This feature is especially useful for calibrating thermostat type controllers with hysteresis.

Dual readout display: A very useful feature of the 1090 is the pressing of a single key to change the display from temperature (°C or °F) to the equivalent uVs or ohms (for PT100-RTD).

Internal Memory and Step functions: Frequently used values can be programmed into the 1090’s non-volatile memory. These can be recalled at any time and stepped through either manually or automatically at a user settable rate.

The 1090 is supplied in a robust case with a carrying strap and compartment for manuals or test leads. Operation, including battery re-charging, is possible without removal from case.

 
 
Printable Version of this page
ENLARGE IMAGE Download Datasheet DOWNLOAD DATASHEET REQUEST A 1090 PRICE QUOTE ONLINE
5011 Res/Temp Calibrator
7000 RTD Temp. Calibrator
1048 V-I Loop Calibrator
1049 PT 100 Simulator