Full Catalogue
Portable Test Instruments
Decade Boxes
Multifunction Calibrators
Programmable Instruments
Process Control Equipment
Calibration Benches
Calibration Software
Accessories
 
Physical
Electrical
 
5051 Multifunction Calibrator
EasyCal Software
1051 Decade Box
TE Calibration Bench
5077 Power Calibrator
5075 Precision DMM
7090 Pneumatic Cal. Pump
1044 Portable DC V/I Cal.
1040 Handheld Resistance Decade Box with high accuracy using high stability metal film resistors
1040 Portable Resistance Box (1 Ohm - 100M Ohm)
Features:

 

High accuracy and precision

 

Clear visual indication

 

High stability and low temperature coefficient

 

Compact and robust

 

Safety Terminals

 

Removable Protective Boot
 
Description:

The 1040 is an accurate hand held decade resistance box designed to meet the needs of industry and education. Housed in a robust metal case the compact construction makes it easily portable.

Excellent accuracy is achieved by using high stability metal film resistors. Mid-scale accuracy is 0.1%. The 8-digit thumbwheel switch enables precise setting with a clear unambiguous indication of the resistance value. The temperature coefficient is better than 50 ppm per ºC. Each resistor has a power rating of 1 watt.

Switch Contacts: Special attention has been given to reliability. A special multiple gold contact switch arrangement ensures that back-up contacts are always available to take over should a contact fail.

Safety Terminals:
Fully compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and spade terminals.

Clear Visual Indication: To prevent misreading, the 1040 incorporates a colour coding system to divide the display into 3 groups to indicate ohms, Kilohms, and Megohms.

Added Protection: The 1040 comes fitted with an ergonomic rubber boot (9028) providing increased protection and durability. The boot has a textured grip for comfortable handling and a raised edge so the 1040 angles slightly upward when resting horizontally. This improves visibility as well as gripping the surface meaning no movement when thumbwheel switches are pressed. It is easy to remove if the user prefers a stand-alone unit or to house the decade box in the 9026 carry case.

The 1040 resistance box is one of Time Electronics' comprehensive decade box range. It is easy-to-operate, portable, and gives the user high accuracy and reliability.

 
 
Printable Version of this page
ENLARGE IMAGE Download Datasheet DOWNLOAD DATASHEET REQUEST A 1040 PRICE QUOTE ONLINE
9028 Protective Boot
9026 Carrying Case
1051 Resistance Box
1041 Resistance Box